xStack® DGS-3420 Series Layer 2+ Managed Stackable Gigabit Switch Hardware Installation Reference Guide
Redundant Power Supply (RPS) Cable
When connecting the Switch to a Redundant Power Supply, an RPS cable is necessary. Please review these products for
matching cable pins.The following diagrams and tables show the standard RPS connector and their pin assignments.
NOTE: The DGS-3420-28PC and the DGS-3420-52P use the RPS-700 and not the RPS-500. Both devices
have their own cables included in the package.
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Pin
1
2
3
4
Figure 5–5 Redundant Power Supply (RPS) Cable – DPS-500/DPS-700
RPS Cable Pin Assignments
Device
GND
+12V
+12V
+12V
+12V
GND
GND
Power Good
Power Present
GND
GND
RPS Cable Pin Assignments
Device
-54Vrtn
-54V
+12V
+12V
NC
NC
NC
48
DPS-500
GND
NC
+12V
+12V
+12V
+12V
GND
GND
Power Good
Power Present
NC
NC
GND
GND
DPS-700
-54Vrtn
-54V
+12V
+12V