Cleaning And Maintenance Instructions; Preparing The Icemaker For Long Storage - Hoshizaki KM-320MAH Service Manual

Modular crescent cuber
Hide thumbs Also See for KM-320MAH:
Table of Contents

Advertisement

VI. Cleaning and Maintenance Instructions
Ensure all components, fasteners and thumbscrews are securely in place after
any maintenance or cleaning is done to the equipment.
A. Preparing the Icemaker for Long Storage
When shutting off the icemaker for an extended time, drain out all water from
the water tank and remove the ice from the storage bin. The storage bin should
be cleaned and dried. Drain the icemaker to prevent damage to the water
supply line at sub-freezing temperatures, using air or carbon dioxide. Shut off
the icemaker until the proper ambient temperature is resumed.
When the icemaker is not used for two or three days, it is sufficient to only move the control
switch to the "OFF" position, unless the icemaker will be at sub-freezing temperatures.
1. On water-cooled model only, first remove the water from the water-cooled condenser:
1) Remove the front panel.
2) Move the control switch on the control box to the "OFF" position.
3) Wait 3 minutes.
4) Move the control switch to the "ICE" position.
5) Allow 5 minutes for the icemaker to fill with water and the water pump to start operating.
6) Close the water-cooled condenser water supply line shut-off valve.
7) Open the drain valve for the water-cooled condenser water supply line.
8) Allow the line to drain by gravity.
9) Attach compressed air or carbon dioxide supply to the condenser water line drain valve.
10) Quickly blow the water-cooled condenser out, using compressed air or carbon dioxide
until water stops coming out.
2. Remove the water from the potable water supply line:
1) Remove the front panel (except water-cooled model).
2) Move the control switch on the control box to the "OFF" position.
3) Wait 3 minutes.
4) Close the potable water supply line shut-off valve and open the potable water supply
line drain valve.
5) Allow the line to drain by gravity.
6) Attach compressed air or carbon dioxide supply to the potable water line drain valve.
7) Move the control switch to the "ICE" position.
8) Blow the potable water line out using compressed air or carbon dioxide.