Hoshizaki KM-320MAH Service Manual page 18

Modular crescent cuber
Hide thumbs Also See for KM-320MAH:
Table of Contents

Advertisement

c) Drain Timer
The drain timer is factory-adjusted, and no adjustment is required.
d) Drain Counter
The drain counter is factory-adjusted to drain the water tank every 10 cycles, and no
adjustment is required. However, where water quality is bad and the icemaker needs a
pump drain more often, the drain counter can be adjusted as shown in the table below:
Dip Switch Setting
No. 3
No. 4
OFF
OFF
ON
OFF
OFF
ON
ON
ON
T1: Time to drain the water tank
T2: Time to restrain defrost completion
Dip Switch Setting
No. 5
No. 6
OFF
OFF
ON
OFF
OFF
ON
ON
ON
Time (seconds)
T1
T2
10
150
10
180
10
120
20
180
Frequency
every cycle
every 2 cycles
every 5 cycles
every 10 cycles
18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-320mwh

Table of Contents