4. KM-1301SWH3 (water-cooled)

APPROXIMATE ICE
PRODUCTION PER 24 HR.
lbs./day kg./day
APPROXIMATE ELECTRIC
CONSUMPTION
watts
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
3
gal./day
m
/day
FREEZING CYCLE TIME
min.
HARVEST CYCLE TIME
min.
HEAD PRESSURE
2
PSIG
kg/cm
G
SUCTION PRESSURE
2
PSIG
kg/cm
G
TOTAL HEAT OF REJECTION FROM CONDENSER
TOTAL HEAT OF REJECTION FROM COMPRESSOR
WATER FLOW FOR CONDENSER
PRESSURE DROP OF COOLING WATER LINE
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior
notice.
AMBIENT TEMP.
(ºF/ºC)
70/21
1333
80/27
1326
90/32
1323
100/38
1286
70/21
80/27
90/32
100/38
70/21
1414
80/27
1499
90/32
1526
100/38
1846
70/21
80/27
90/32
100/38
70/21
80/27
90/32
100/38
70/21
237
80/27
238
90/32
238
100/38
244
70/21
50
80/27
50
90/32
50
100/38
51
46
WATER TEMP. (ºF/ºC)
50/10
70/21
605
1323
601
1311
600
1300
584
1277
1770
1791
1786
1818
1791
1840
1789
1842
5.35
1526
5.68
1673
5.78
1795
6.99
1944
30
31
31
32
32
31
31
33
4.5
3.8
3.0
4.0
3.8
2.4
3.1
2.3
16.7
238
16.7
239
16.7
240
17.1
244
3.5
50
3.5
49
3.5
49
3.6
50
17,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
2,300 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
119 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
less than 10 PSIG
90/32
600
1246
565
594
1198
544
590
1201
545
579
1110
503
1805
1824
1850
1860
5.78
2036
7.71
6.33
2382
9.02
6.80
2431
9.20
7.36
3015
11.41
32
33
34
35
3.5
3.0
2.2
2.1
16.7
249
17.5
16.8
256
18.0
16.9
255
17.9
17.1
269
18.9
3.5
52
3.7
3.5
53
3.7
3.4
52
3.7
3.5
55
3.9

Hide quick links: