Controls And Adjustments; A) Default Dip Switch Settings; B) Harvest Timer (S4 Dip Switch 1 & 2) - Hoshizaki KM-1301SAH/3 Service Manual

Stackable crescent cuber
Hide thumbs Also See for KM-1301SAH/3:
Table of Contents

Advertisement

3. Controls and Adjustments

Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact
Hoshizaki Technical Support at 1-800-233-1940.

a) Default Dip Switch Settings

The dip switches are factory set to the following positions:
S4 Dip Switch No.
KM-1301SAH/3
KM-1301SWH/3
KM-1301SRH/3
S5 Dip Switch (Do Not Adjust)
S5 Dip Switch No. 1
KM-1301SAH/3
KM-1301SWH/3
KM-1301SRH/3
b) Harvest Timer (S4 dip switch 1 & 2)
The harvest timer starts when the thermistor reads 48°F (9°C) at the evaporator outlet
and the control board reads the thermistor's 3.9 KΩ signal. The harvest timer is factory
set, and generally no adjustment is required. However, a setting longer than the factory
setting may be advised in cases where the flush provided at harvest needs to be
prolonged for extra cleaning. Before changing this setting, contact Hoshizaki Technical
Support at 1-800-233-1940 for recommendations. Keep in mind that setting the harvest
timer to a longer setting decreases 24-hour production.
S4 Dip Switch
1
2
3
4
OFF OFF ON ON ON ON ON OFF OFF OFF
OFF OFF ON ON ON ON ON OFF OFF OFF
OFF OFF ON ON ON ON ON OFF ON OFF
2
3
4
5
OFF OFF OFF OFF OFF
OFF OFF OFF OFF OFF
OFF OFF OFF OFF OFF
S4 Dip Switch Setting
No. 1
OFF
ON
OFF
ON
CAUTION
5
6
7
8
9
Pump-Out Frequency Control (5 & 6)
Pump-Out Timer (3 & 4)
(Do not adjust to 3 off and 4 on)
Harvest Timer (1 & 2)
Time
(seconds)
No. 2
OFF
60
OFF
90
ON
120
ON
180
25
10
Freeze Timer (9 & 10)
Factory Use (8)
Harvest Pump Timer (7)
(Do not adjust)