6. KM-1301SRH3 (remote air-cooled)

AC SUPPLY VOLTAGE
AMPERAGE
MINIMUM CIRCUIT AMPACITY
MAXIMUM FUSE SIZE
APPROXIMATE ICE PRODUCTION
PER 24 HR.
lbs./day ( kg/day )
Reference without *marks
SHAPE OF ICE
ICE PRODUCTION PER CYCLE
APPROXIMATE STORAGE CAPACITY
ELECTRIC & WATER CONSUMPTION
ELECTRIC
W (kWH/100 lbs.)
WATER gal./24HR (gal./100 lbs.)
CEC/CEE TIER LEVEL
ENERGY STAR
EXTERIOR DIMENSIONS (WxDxH)
EXTERIOR FINISH
WEIGHT
CONNECTIONS - ELECTRIC
- WATER SUPPLY
- DRAIN
- CONDENSATE DRAIN
CUBE CONTROL SYSTEM
HARVESTING CONTROL SYSTEM
ICE MAKING WATER CONTROL
COOLING WATER CONTROL
BIN CONTROL SYSTEM
COMPRESSOR
CONDENSER
EVAPORATOR
REFRIGERANT CONTROL
REFRIGERANT CHARGE
DESIGN PRESSURE
P.C. BOARD CIRCUIT PROTECTION
COMPRESSOR PROTECTION
REFRIGERANT CIRCUIT PROTECTION
LOW WATER PROTECTION
ACCESSORIES -SUPPLIED
-REQUIRED
OPERATING CONDITIONS
Note: We reserve the right to make changes in specifications and design without prior
notice.
208-230/60/3
10.7A ( 5 Min. Freeze AT 104°F / WT 80°F)
20 A
20 A
Ambient
Temp.(°F)
50
70
*1339 (607)
80
1307 (593)
90
1297 (589)
100
1266 (574)
Crescent Cube
30.7 lbs. (13.9 kg) 1440pcs.
N/A
90/70°F
2140(4.3)
192(16.0)
3
YES
48" x 27-3/8" x 27-3/8" (1219 x 695 x 695 mm)
Stainless Steel, Galvanized Steel (Rear)
Net 255 lbs. (116 kg), Shipping 315 lbs. (143 kg)
Permanent - Connection
Inlet
1/2" FPT
Outlet
3/4" FPT
3/8" OD Tube
Float Switch
Hot Gas and Water, Thermistor and Timer
Timer Controlled. Overflow Pipe
N/A
Thermostat
Hermetic, Model CS12K6E-TF5-279
Air-Cooled Remote, Condenser Unit URC-14F
Vertical type, Stainless Steel and Copper
Thermostatic Expansion Valve
Condensing Pressure Regulator on URC-14F
R404A, 10 lbs. 5.8 oz. (4700g)
(Icemaker 5 lbs. 15.2 oz. Cond. Unit 4 lbs. 6.5 oz.)
High 467PSIG, Low 230PSIG
High Voltage Cut-out ( Internal )
Auto-reset Overload Protector ( Internal )
Auto-reset High Pressure Control Switch
Float Switch
N/A
Ice Storage Bin, Remote Condenser Unit
VOLTAGE RANGE
AMBIENT TEMP.
WATER SUPPLY TEMP.
WATER SUPPLY PRESSURE
12
WATER TEMP. (°F)
70
1297 (589)
1203 (546)
1243 (564)
1127 (511)
*1197 (543)
1088 (494)
1171 (531)
988 (448)
70/50°F
2090(3.8)
463(34.6)
187 - 253 V
10 - 113 PSIG
90
45 -100° F
45 - 90° F