Final Checklist - Hoshizaki KM-101BAH Instruction Manual

Self-contained crescent cuber
Hide thumbs Also See for KM-101BAH:
Table of Contents

Advertisement

G. Final Checklist
1) Is the icemaker level?
2) Is the icemaker in a site where the ambient temperature is within +45°F to +100°F (+7°
C to +38°C) and the water temperature within +45°F to +90°F (+7°C to +32°C) all year
around?
3) Is there at least 0.6" (15 mm) clearance at top of the icemaker for ease of maintenance
or service?
4) Have all shipping carton, tape(s) and packing been removed from the icemaker? Is the
cube guide in its correct position?
5) Are all components, fasteners and screws securely in place?
6) Have all electrical and piping connections been made?
7) Has the power supply voltage been checked or tested against the nameplate rating?
And has a proper ground been installed in the icemaker?
8) Are the water supply line Shut-off Valve and Drain Valve installed? Has the water
supply pressure been checked to ensure a minimum of 10 PSIG (0.7 bar) and a
maximum of 113 PSIG (7.5 bar)?
Note: The icemaker may stop running when the water supply is OFF, or if the pressure
is below 10 PSIG (0.7 bar). When the proper water pressure is reached, the
icemaker automatically starts running again.
9) Have the Compressor hold-down bolts and all refrigerant lines been checked against
vibration and possible failure?
10) Has the bin control operation been verified?
11) Has the end user been given the Instruction Manual and instructed on how to operate
the icemaker and the importance of the recommended periodic maintenance?
12) Has the end user been given the name and telephone number of an authorized service
agent?
13) Has the warranty card been filled out and forwarded to the factory for warranty
registration?
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-151bahKm-151bwhKm-61bah

Table of Contents