Dispense Mode Switch; Alarm Safeties - Hoshizaki DCM-500B H Instruction Manual

Cubelet icemaker/dispenser
Table of Contents

Advertisement

I. Dispense Mode Switch
The dispense mode switch has "CONTINUOUS" and "PORTION" positions. When the
dispense mode switch is in the "CONTINUOUS" position, ice dispenses continuously
for a maximum of 60 seconds per activation. When the dispense mode switch is in
the "PORTION" position, ice dispenses for the amount of time determined by the ice
dispense time setting. The ice dispense time control is located on the control board.
The dial indicates dispense time in seconds and is adjustable between 0.6 and 20
seconds. See Fig. 8. When shipped, the ice dispense time control is set to the minimum
dispense time of 0.6 sec. At this setting, approximately 0.72 oz. of ice is dispensed.
Approximately 1.2 oz. of ice is dispensed per second.
J. Alarm Safeties
Should an alarm occur, follow the instructions in the table below to address the alarm.
If an alarm continues to occur, contact an authorized service agent.
• Only qualified service technicians should service the appliance.
• To reduce the risk of electric shock, do not touch the icemaker power switch or
control switch with damp hands.
• Before Servicing: Move the icemaker's power switch to the "OFF" position. Turn
off the power supply. Lockout/Tagout to prevent the power supply from being turned
back on inadvertently.
No. of Beeps
(every 5 sec.)
1
Low Water Safety
UFS open>90 sec. after WV energized.
Control Switch
2
In "DRAIN" position longer than 10 min.
3
High-Pressure Switch
First and second activation in 1 hr.
4
High-Pressure Switch
Third activation in 1 hr.
5
Freeze Timer
WV off > 30 min. since last WV activation.
Low Voltage
6
92VAC±5% or less
7
High Voltage
147VAC±5% or more
Gear Motor
8
CCR contacts fail to close.
Legend: CCR–compressor control relay; UFS–upper float switch; HPS–high-pressure
switch; WV–inlet water valve
WARNING
Type of Alarm
23
Reset Options
Automatic reset once water supply is restored
and UFS closes.
Automatic reset once the control switch is
moved to the "ICE" position.
Automatic reset once pressure drops below
the high pressure threshold and HPS closes.
Call for service. To avoid possible catastrophic
failure, it is recommended to leave the
icemaker off until this alarm is resolved.
Manual reset. Turn power off and on again.
Manual reset. Turn power off and on again.
"POWER OK" LED turns off if voltage
protection operates.
The control voltage safeties automatically
reset when voltage is corrected.
Manual reset. Turn power off and on again.