Four inch (approx. 100 mm)
diameter ducting should be used.
Use either rigid metal or flexible
metal ducting material.
DO NOT use plastic or non metal
duct with this dryer.
DO NOT assemble the ductwork
with screws or fasteners that
extend into the duct. They will serve
as an accumulation point for lint.
Joints should be secured with duct
tape.
All joints should be tight to avoid
leaks. The male end of each duct
section must point away from the
dryer.
Exhaust vent hood
The exhaust duct must end with an
approved exhaust vent hood with
swing out damper(s). DO NOT use
an exhaust vent hood with
magnetic latches.
To avoid exhaust restriction, the
outlet must be a minimum of
12 inches (30 cm) above ground
level or any other obstructing
surface.
Installation
step by step
1. Unpack the dryer.
2. Remove all objects from the
drum.
3. Check the dryer for visible
damage.
4. Position the dryer near the
installation location.
5. If required, have the power
supply cord fitted by an
electrician (see page 8).
If space is very restricted, it is
i
recommended to fit the
exhaust air duct to the dryer
before the dryer is moved to its
final installation location.
6. Connect the exhaust air duct to
the exhaust air outlet on the
dryer. Fix the air duct with duct
clamp.
7. Move the dryer to its final
location and align.
d
CAUTION
Do not slide dryer across the
floor if height adjustable feet
have been extended. Feet and/or
dryer base may be damaged if
dryer is slid across floor with
height adjustable feet extended.
8. Position and then level the
dryer .
The dryer should be level with
all four feet firmly on the
ground. The dryer must not
wobble. If the dryer is not level
or if it does wobble, the feet
d
must be adjusted. Adjust the
height adjustable feet until the
dryer does not rock and is level,
both front to back and
side to side.
9. Insert plug into the wall
receptacle.
11