IBM System x3550 M4 Installation And User Manual page 42

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

DC power-supply LEDs
IN OK
OUT OK
On
Off
On
Off
On
On
26
IBM System x3550 M4 Type 7914: Installation and User's Guide
Error (!)
Description
Off
Power-supply not
fully seated, faulty
system board, or
the power supply
has failed.
On
The power supply
has failed.
On
The power supply
has failed.
Action
1. Reseat the power supply.
2. Follow actions in the "Power
problems" under the
Troubleshooting tables in the
Problem Determination and
Service Guide.
3. If the OVER SPEC LED on
the light path diagnostics is
lit, follow the actions in "Light
path diagnostics LEDs" on
page 17.
4. If the OVER SPEC LED on
the light path diagnostics is
not lit, check the error LEDs
on the system board and the
IMM2 error messages. Follow
steps in the "Power
problems" under the
Troubleshooting tables in the
Problem Determination and
Service Guide and "Solving
Power problems" in the
Problem Determination and
Service Guide until the
problem is solved.
Replace the power supply.
Replace the power supply.
Notes
Typically indicates a
power-supply is not
fully seated.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X3550 m47914

Table of Contents