Place the server on a sturdy, level surface.
5.
Remove the access panel
WARNING:
internal system components to cool before touching them.
CAUTION:
Operating the server in this manner results in improper airflow and improper cooling that can
lead to thermal damage.
To remove the component:
Power down the server (on page 15).
1.
Remove the server from the rack (on page 15).
2.
Open the latch, slide the access panel to the rear of the chassis, and remove the access panel.
3.
If the latch is locked, use a T-15 Torx screwdriver to unlock the latch.
Remove the air baffle
To remove the component:
Power down the server (on page 15).
1.
Remove the server from the rack (on page 15).
2.
Remove the access panel (on page 16).
3.
To replace the component, reverse the removal procedure.
Remove the PCI riser board assembly
To reduce the risk of personal injury from hot surfaces, allow the drives and the
Do not operate the server for long periods with the access panel open or removed.
Operations 16