Installing a hot-swap power supply

The following notes describe the type of ac power supply that the server supports
and other information that you must consider when you install a power supply:
v Make sure that the devices that you are installing are supported. For a list of
v Before you install an additional power supply or replace a power supply with one
v The server comes with one hot-swap 12-volt output power supply that connects
v Power supplies in the server must be with the same power rating or wattage to
v Power supply 1 is the default/primary power supply. If power supply 1 fails, you
v You can order an optional power supply for redundancy.
v These power supplies are designed for parallel operation. In the event of a
Statement 5:
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.
Statement 8
106
IBM System x3500 M4 Type 7383: Installation and User's Guide
Note: If the grease is properly applied, approximately half of the grease will
remain in the syringe.
supported optional devices for the server, see http://www.ibm.com/systems/info/
x86servers/serverproven/compat/us/.
of a different wattage, you may use the IBM Power Configurator utility to
determine current system power consumption. For more information and to
download the utility, go to http://www-03.ibm.com/systems/bladecenter/resources/
powerconfig.html.
to power supply bay 1. The input voltage is 110 V ac or 220 V ac auto-sensing.
ensure that the server will operate correctly.
must replace the power supply with the same wattage immediately.
power-supply failure, the redundant power supply continues to power the system.
The server supports a maximum of two power supplies.