Data Sheet
FUJITSU Server PRIMERGY RX300 S8 Dual socket 2U rack server
Server Management
Option
Server Management notes
Dimensions / Weight
Rack (W x D x H)
Mounting Depth Rack
Height Unit Rack
19" rackmount
Weight
Weight notes
Rack integration kit
Environmental
Operating ambient temperature
Operating temperature note
Operating relative humidity

Operating environment

Operating environment Link
Noise emission
Sound pressure (LpAm)
Sound power (LWAd; 1B = 10dB)
Noise notes
Electrical values
Power supply configuration
Max. output of single power supply
Power supply efficiency
Hot-plug power supply output
Hot-plug power supply redundancy
Rated voltage range
Rated frequency range
Rated current max.
Rated current in basic configuration
Active power (min. configuration)
Active power (max. configuration)
Active power note
Apparent power (max. configuration)
Heat emission
Power Supply Notes
Page 7 / 11
ServerView Suite - Deploy
SV Deployment Manager (full version)
ServerView Suite - Maintain
iRMC Advanced Pack incl. Advanced Video Redirection (AVR) and Remote Storage
ServerView Suite - Dynamize
SV Virtual-IO Manager (VIOM)
SV Resource Orchestrator Virtual Edition (ROR VE)
SV Resource Orchestrator Cloud Edition (ROR CE)
ServerView Suite - Integrate
SV Integration pack for Fujitsu ManageNow® solution
Regarding Operating System dependencies for ServerView Suite Software Products see dedicated Product Data sheets.
482.6 mm (Bezel) / 445mm (Body) x 770 x 86.9 mm
735 mm
2 U
Yes
up to 25 kg
Actual weight may vary depending on configuration
Rack integration kit as option
5 - 40 °C
Cool-Safe© Advanced Thermal Design (above 35 °C or below 10 °C) depending on configuration. For detailed
information see relevant system configurator.
10 - 85 % (non condensing)
FTS 04230 – Guideline for Data Center (installation specification)
http://docs.ts.fujitsu.com/dl.aspx?id=e4813edf-4a27-461a-8184-983092c12dbe
Measured according to ISO 7779 and declared according to ISO 9296
Minimum noise : 23 dB(A) (idle) / 22 dB(A) (operating)
Typical noise : 48 dB(A) (idle) / 49 dB(A) (operating)
Minimum noise : 3.9 B (idle) / 3.8 B (operating)
Typical noise : 6.5 B (idle) / 6.6 B (operating)
Noise emissions and operation modes depend on system configuration.
1-2x 450 W / 800 W hot-plug power supply
450 W (94 % efficiency); 800 W (94 % / 96 % efficiency)
94 % (80 PLUS platinum)
96 % (80 PLUS titanium)
450 W (94 % efficiency); 800 W (94 % / 96 % efficiency)
Yes
100 V - 240 V
47 Hz - 63 Hz
8.2 A (100 V) / 3.3 A (240 V)
100 V - 240 V / TBD
53 W
830 W
To estimate the power consumption of different configurations use the Power Calculator of the System Architect: http://
configurator.ts.fujitsu.com/public/
873 VA
2988.0 kJ/h (2832.1 BTU/h)
Power Safeguard adapts system performance in case the wattage exceeds supply limits.
www.fujitsu.com/fts