4. See screen below to review how the thermostat keys are
used during Installer Setup. See Table 3–4 for the
Installer Setup Numbers and Settings.
ISU
Parameter
Installer Setup
Number
Name
110
Zone Number
120
Date (Year
USU
Upper)
130
Date (Year
USU
Lower)
140
Date (Month)
USU
150
Date (Day)
USU
160
Schedule Options 4
USU
165
Restore energy
USU
saving default
schedule
172
System Selection 1
173
Heat Pump Type 0
174
Number of Cool/
Compressor
Stages
176
Number of
Conventional
Heat or Heat
Pump Aux Stages
180
Fan Operation
Conventional
heat only
Table 3. Installer Setup Menu.
Settings
(Factory Defaults Shown in Bold)
0
Not zoned
1–9
Zone number
20
21
01-99
Default = 06
1-12
Default = 06
Select number that represents current
calendar month.
1-31
Default = 15
Select number that represents current
calendar date.
Seven-day programmable
0
Non-programmable
0
No
1
Yes
Conventional
2
Heat Pump
3
Heat Only No Fan
E
Auto Discover
Air to Air heat pump
1
Geothermal heat pump
1
1
0
none
2
2
E
Auto Discover
1
1
0
none
2
2
3
3
E
Auto Discover
0
Gas or oil furnace equipment controls fan
in heating
1
Electric furnace—thermostat controls fan in
heating
2
Equipment controls stage 1; thermostat
controls stage 2+
E
Auto Discover
VISIONPRO
INSTALLER
SETUP
NUMBER
MON
DONE
O
PRESS TO EXIT
INSTALLER SETUP
5. Press the Done key to exit the Installer Setup screen.
Select zone number.
Zone 0 = not zoned
Zone 1 = master zone controller*
Zone 2–9 = satellite thermostat*
*Only change if used with Envirazone Panel.
Select first two digits of current calendar year (2006
for example) - (2001-2178 available).
Select last two digits of current calendar year (2006
for example) - (2001-2178 available).
Selection of a specific system setting will
automatically modify some default settings and/or
hide other installer setup options that follow.
Not shown if ISU172 = 3.
Conventional systems = number of cooling stages.
Heat Pump systems = number of compressor
stages.
Conventional systems = number of heating stages
(maximum of 3).
Heat Pump systems = number of auxiliary heat
stages (maximum of 2).
Only shown if ISU172 = 1 (conventional system).
Use 0 for fossil fuel systems (equipment controls
fan).
Use 1 for electric systems (thermostat controls fan).
Use 2 if stage 1 is radiant heating and stage 2+ is a
hot water fan coil.
13
®
IAQ TOTAL HOME COMFORT SYSTEM
ADVANCE TO NEXT
INSTALLER SETUP
CURRENT
SETTING
WED
THU
U
FRI
SAT A A T
A
SUN
CHANGE THE
CURRENT
SETTING
Notes
M22443