Honeywell VISIONPRO 68-0287-04 User Manual page 17

Iaq total home comfort system
Table of Contents

Advertisement

ISU
Parameter
Installer Setup
Number
Name
394
Southern
Dehumidification
Away
Dehumidification
Setting
400
Ventilation control 0
401
Number of
bedrooms
402
Total house
Sq. Ft.
403
Ventilation CFM
404
Max ventilation
percentage limit
405
Ventilation Fan
Action
406
Ventilation in
High Humidity
430
Ventilation
lockout
431
Ventilation
lockout high
temperature
432
Ventilation
lockout low
temperature
450
DATS Inhibit
500
Furnace Filter
USU
Change
Reminder
502
Furnace filter
reminder run time
equipment counts
Table 3. Installer Setup Menu. (Continued)
Settings
(Factory Defaults Shown in Bold)
65
Default = 65%
40-70
40%–70% relative humidity
No ventilation
1
Ventilation on at all times
2
Ventilation on except during sleep period
3
Vent all with lockouts
4
Vent off sleep with lockouts
2
Default = 2
1-6
1–6 bedrooms
10
Default = 1000 sq. ft.
10-50
1000–5000 sq. ft. in increments of 100
160
Default = 160 CFM
30-195
30–195 CFM in increments of 5
50
Default = 50%
30-60
30%–60%
100
unlimited
1
Vent on will force fan on also
2
Vent will not force fan ON
1
On
0
Off
0
Disabled
1
Lockout for high temperatures
2
Lockout for low temperatures
3
Lockout for high and low temperatures
100
38
100°F
38°C
90
32
90°F
32°C
95
35
95°F
35°C
105
40.5
105°F
40.5°C
110
43.5
110°F
43.5°C
-10
-23.5
-10°F
-23.5°C
-20
-29
-20°F
-29.0°C
-15
-26
-15°F
-26.0°C
-5
-20.5
-5°F
-20.5°C
-0
-18
0°F
-18.0°C
0
Disabled
35
1.5
35°F
1.5°C
40
4.5
40°F
4.5°C
45
7
45°F
7.0°C
50
10
50°F
10.0°C
55
13
55°F
13.0°C
60
15.5
60°F
15.5°C
65
18.5
65°F
18.5°C
E
Auto Discover
0
Disabled
1
10 R.T. Days
2
30 R.T. Days
3
60 R.T. Days
4
90 R.T. Days
5
120 R.T Days
6
180 R.T. Days
7
270 R.T. Days
8
365 R.T. Days
9
30 C Days
10
60 C Days
11
90 C Days
12
120 C Days
13
180 C Days
14
365 C Days
0
Counts runtime Heat and Cool
1
Counts runtime Cool only
VISIONPRO
Set the desired humidity level to maintain within the
living space
If ISU300 = 0, ISU401-405 will not be shown.
Not ASHRAE
Not ASHRAE
The thermostat will determine if ventilation is
meeting ASHRAE standard 62.2. The display will
show a P above the setup number if the setting
passes the ASHRAE standard, or F if it does not.
Best practice is to move the setting down until F is
displayed, then move up one setting to the minimum
passing value.
Only shown if ISU372 and ISU400 are not set to 0.
When set to On will use ventilation to remove
humidity when thermostat is in the heat mode.
Outdoor temperature sensor required for high and
low temperature lockouts.
The DATS will cycle the cooling off at the selected
temperature to prevent coil freezing.
17
®
IAQ TOTAL HOME COMFORT SYSTEM
Notes
68-0287—04