ISU
Parameter
Installer Setup
Number
Name
340
Indoor Temp
Sensor
342
Outdoor Temp
Sensor
345
Dual Fuel Heat
Pump Control
346
Dual Fuel Heat
Pump Upstage to
Furnace Timer (in
hours)
347
Droop
Temperature
350
Heat Pump
Balance Point
(also compressor
lockout)
Temperature
360
Heat Pump
Auxiliary Heat
Lockout
Temperature
365
Discharge Temp
Sensor
366
Zoning High
Temperature
Limit
367
Zoning Low
Temperature
Limit
Table 3. Installer Setup Menu. (Continued)
Settings
(Factory Defaults Shown in Bold)
0
Thermostat location only
1
Remote indoor sensor(s) location(s) only
2
Average between thermostat and sensor
locations
E
Auto Discover
0
None
1
Yes
1
Droop Control
0
No Droop Control
2
Droop Control with Auxiliary heat lockout
1
1 hr.
0
Disabled
0.5
0.5 hrs.
1.5
1.5 hrs.
2
2 hrs.
3
3 hrs.
4 hrs.
4
5
5 hrs.
6
6 hrs.
8
8 hrs.
10
10 hrs.
12
12 hrs.
14
14 hrs.
16
16 hrs.
2
2°F
1.0°C
3
3°F
1.5°C
4
4°F
2.0°C
5
5°F
2.5°C
40
4.5
40°F
4.5°C
0
No heat pump compressor lockout
5
-15
5°F
-15.0°C
10
-12
10°F
-12.0°C
15
-9.5
15°F
-9.5°C
20
-6.5
20°F
-6.5°C
25
-4
25°F
-4.0°C
30
-1
30°F
-1.0°C
35
1.5
35°F
1.5°C
45
7
45°F
7.0°C
50
10
50°F
10.0°C
55
13
55°F
13.0°C
60
15.5
60°F
15.5°C
(Show 1/2 degree C)
0
No heat pump auxiliary lockout
5
-15
5°F
-15.0°C
10
-12
10°F
-12.0°C
15
-9.5
15°F
-9.5°C
20
-6.5
20°F
-6.5°C
25
-4
25°F
-4.0°C
30
-1
30°F
-1.0°C
35
1.5
35°F
1.5°C
40
4.5
40°F
4.5°C
45
7
45°F
7.0°C
50
10
50°F
10.0°C
55
13
55°F
13.0°C
60
15.5
60°F
15.5°C
65
18.5
65°F
18.5°C
(Show 1/2 degree C)
E
Auto Discover
0
None
1
Remote
160
160°F (71°C)
0
Disabled
110–170
110°F to 170°F (43.5°C to 76.5°C)
40
160°F (71°C)
0
Disabled
35-50
35°F to 50°F (1.5°C to 10°C)
VISIONPRO
Indoor temperature sensors will display the
temperature at the sensor location or an average of
two indoor temperature sensors, not including the
temperature sensor in the thermostat. The
temperature sensor in the thermostat is disabled
when using remote indoor temperature sensor(s).
An outdoor temperature sensor is required for heat
pump compressor lockout (ISU350), heat pump
auxiliary lockout (ISU360), dual fuel heat pump
balance point (ISU360) and Humidification with
Frost Protection (ISU372).
See Dual Fuel Heat Pump control on page 23.
See Dual Fuel Heat Pump control on page 23.
The fossil fuel will turn on when the outdoor
temperature is above the balance point if the room
temperature droops below the selected droop
temperature setting, and the compressor will be
disabled.
Only shown for heat pump applications with an
outdoor temperature sensor present.
If electric backup is selected then the default is No
Compressor lockout.
Only shown for heat pump applications with an
outdoor temperature sensor present.
Only Shown if ISU110 = 1 (Master Zone Controller)
and Discharge Temperature Sensor is available.
Only Shown if ISU110 = 1 (Master Zone Controller)
and Discharge Temperature Sensor is available.
15
®
IAQ TOTAL HOME COMFORT SYSTEM
Notes
68-0287—04