Test Procedure - Sharp R-202EW Service Manual

Hide thumbs Also See for R-202EW:
Table of Contents

Advertisement

R-202EW
R-203EW

TEST PROCEDURE

POSSIBLE CAUSE
DEFECTIVE PARTS
PROBLEM
CONDITION
Home fuse blows when power cord
is plugged into wall receptacle.
C/T fuse blows when power cord is
plugged into wall receptacle.
Any letters or indicators do not ap-
pear in display when power cord is
first plugged into wall outlet.
OFF
CONDITION
Display does not operate properly
when STOP/CLEAR key is touched.
(Buzzer should sound and time of
day should appear in display.)
C/T fuse blows when the door is
opened.
Fan motor does not operate. (All
other electric components function.)
Oven lamp does not light at all. (All
other electric components function.)
Turntable motor does not operate. (All
other electric components function.)
Oven does not go into cook cycle
when START pad is touched
Oven seems to be operating but little
COOKING
or no heat is produced in oven load.
CONDITION
(Food incompletely cooked or not
cooked at all at end of cook cycle.)
Oven goes into a cook cycle but
extremely uneven heating is pro-
duced in oven load (food).
Oven does not cook properly when
programmed for Cooking Power 5
mode. (Operates properly on Cook-
ing Power 10 (HIGH) mode.)
Oven lamp, turntable motor and fan
motor do not operate.
Oven goes into EXPRESS DEFROST
but food is not defrosted well.
PROCEDURE
LETTER
A
MAGNETRON ASSEMBLY TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. To test for an open filament, isolate the magnetron from the high voltage circuit. A continuity check
across the magnetron filament leads should indicate less than 1 ohm.
A B C D E F
RE CK
AND
TEST PROCEDURES
F G H
RE RE CK
COMPONENT TEST
10
CK = Check / RE = Replace
I/K
CK CK CK J
M L

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-203ew

Table of Contents