CAUTION:
• Do not hit the fan blade strongly when installed
because the bracket may be transformed.
• Make sure that the fan blade rotates smooth after
installed.
• Make sure that the axis of the shaft is not slanted.
6. Install the fan motor assembly to the oven cavity with
three (3) screws.
Coil
Groove joint pliers
Stator
Gap
Bracket
Rotor
Rear View
DOOR SENSING SWITCH/SECONDARY INTERLOCK SWITCH AND MONITOR SWITCH REMOVAL
1. Disconnect the power supply cord and remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect wire leads from the switches.
5. Remove two (2) screws holding latch hook to oven
flange.
6. Remove the switch lever from the oven cavity
7. Remove latch hook assembly from oven flange.
8. Push outward on the two (2) retaining tabs holding switch
in place.
9. Switch is now free.
DOOR SENSING SWITCH/SECONDARY INTERLOCK SWITCH AND MONITOR SWITCH ADJUSTMENT
1. Disconnect the power supply cord, and then remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
If the door sensing switch, secondary interlock switch and
monitor switch do not operate properly due to a
misadjustment, the following adjustment should be made.
4. Loosen the two (2) screws holding latch hook to the oven
cavity front flange.
5. With door closed, adjust latch hook by moving it back and
forth, and up and down. In and out play of the door
allowed by the upper and lower position of the latch hook
should be less than 0.5mm. The vertical position of the
latch hook should be adjusted so that the door sensing
switch and secondary interlock switch are activated with
the door closed. The horizontal position of the latch hook
should be adjusted so that the plunger of the monitor
switch is pressed with the door closed.
6. Secure the screws with washers firmly.
7. Check the operation of all switches. If each switch has
not activated with the door closed, loosen screw and
adjust the latch hook position.
After adjustment, check the following.
1. In and out play of door remains less than 0.5mm when in
the latched position. First check upper position of latch
7. Re-install the C/T fuse to the oven cavity with the one (1)
screw.
8. Install the magnetron with three (3) screws.
9. Re-install the wire leads of the fan duct.
10.Connect the wire leads to the magnetron and the fan
motor, referring to the pictorial diagram.
Shaft
These are the positions
Axis
that should be pinched
with pliers.
Stator
Rotor
Side View
Re-install
1. Re-install each switch in its place. The secondary
interlock/monitor switches are in the lower position and
the door sensing switch is in the upper position.
2. Re-connect wire leads to each switch.
Refer to pictorial diagram.
3. Secure latch hook (with two (2) mounting screws) to
oven flange.
4. Install the switch lever to the oven cavity
5. Make sure that the monitor switch is operating properly
and check continuity of the monitor circuit. Refer to
chapter "Test Procedure" and Adjustment procedure.
hook, pushing and pulling upper portion of door toward
the oven face. Then check lower portion of the latch
hook, pushing and pulling lower portion of the door
toward the oven face. Both results (play in the door)
should be less than 0.5mm.
2. The door sensing switch and secondary interlock switch
interrupt the circuit before the door can be opened.
3. Monitor switch contacts close when door is opened.
4. Re-install outer case and check for microwave leakage
around door with an approved microwave survey meter.
(Refer to Microwave Measurement Procedure.)
25
Table
Latch Heads
Door
Switch Lever
Figure C-3. Latch Switch Adjustments
R-202EW
R-203EW
Shaft
Center of
bracket
Latch Hook
Door
Sensing
Switch
Monitor
Switch
Secondary
Interlock
Switch