Component Replacement And Adjustment Procedure; Outer Case Removal - Sharp R-202EW Service Manual

Hide thumbs Also See for R-202EW:
Table of Contents

Advertisement

R-202EW
R-203EW

COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE

Microwave ovens contain circuitry capable of producing very high voltage and current, contact with following parts may
result in severe, possibly fatal, electric shock.
(Example)
High Voltage Capacitor, Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage Harness etc..
Avoid possible exposure to microwave energy. Please follow the instructions below before
WARNING:
operating the oven.
1. Disconnect the power supply cord.
2. Make sure that a definite" click" can be heard when the
microwave oven door is unlatched. (Hold the door in a
closed position with one hand, then push the door open
button with the other, this causes the latch leads to rise,
it is then possible to hear a "click' as the door switches
operate.)
3. Visually check the door and cavity face plate for damage
(dents, cracks, signs of arcing etc.).
Carry out any remedial work that is necessary before
operating the oven.
Do not operate the oven if any of the following conditions
exist;
To prevent an electric shock, take the following pre-
cautions.
1. Before wiring,
1) Disconnect the power supply cord.
2) Open the door block it open.
3) Discharge the high voltage capacitor and wait for 60
seconds.
2. Don't let the wire leads touch to the following parts;
1) High voltage parts:
Magnetron, High voltage transformer, High voltage
capacitor and High voltage rectifier assembly.
2) Hot parts:
Oven lamp, Magnetron, High voltage transformer
and Oven cavity.
Please refer to 'OVEN PARTS, CABINET PARTS, CONTROL PANEL PARTS, DOOR PARTS', when carrying out any of
the following removal procedures:
To remove the outer case, procedure as follows.
1. Disconnect the power supply cord.
2. Open the oven door and block it open.
3. Remove the two (2) screws from the lower portion of the
rear cabinet using a T20H Torx type or GTXH20-100
screw driver.
4. Remove the remaining three (3) screws from the upper
portion of the rear and two (2) screws along the left side
of outer case.
5. Slide the entire outer case back out about 1 inch (3 cm)
WARNING AGAINST HIGH VOLTAGE:
WARNING FOR WIRING

OUTER CASE REMOVAL

1. Door does not close firmly.
2. Door hinge, support or latch hook is damaged.
3. The door gasket or seal is damaged.
4. The door is bent or warped.
5. There are defective parts in the door interlock system.
6. There are defective parts in the microwave generating
and transmission assembly.
7. There is visible damage to the oven.
Do not operate the oven:
1. Without the RF gasket (Magnetron).
2. If the wave guide or oven cavity are not intact.
3. If the door is not closed.
4. If the outer case (cabinet) is not fitted.
3) Sharp edge:
Bottom plate, Oven cavity, Waveguide flange,
Chassis support and other metallic plate.
4) Movable parts (to prevent a fault)
Fan blade, Fan motor, Switch, Switch lever, Open
button.
3. Do not catch the wire leads in the outer case cabinet.
4. Insert the positive lock connector until its pin is locked
and make sure that the wire leads do not come off even
if the wire leads are pulled.
5. To prevent an error function, connect the wire leads
correctly, referring to the Pictorial Diagram.
Special Screw
22
Screw Driver
Type: TORX T20 H or
GTXH20-100

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-203ew

Table of Contents