[ZIVA DEBUG MODE]
• This mode is used to unable to reset for performing the debug of
ziva.
Procedure:
1. Press the
button to turn the power ON.
I/1
[FUNCTION]
2. Press the
button to select "DVD".
3. Press three buttons of
Y
simultaneously.
4. Ziva debug mode is set.
[COLOR SYSTEM CHANGE-OVER]
(Saudi Arabia, Singapore, Malaysia and Australian
model)
• This mode is used to changed over color system.
Procedure:
1. Press the
button to turn the power ON.
I/1
[FUNCTION]
2. Press the
button to select "DVD".
3. Press the
button to turn the power OFF.
I/1
4. Press two buttons of
X
and
5.
The message "COLOR NTSC" or "COLOR PAL" is displayed
on the liquid crystal display, and the color system is changed
over NTSC or PAL.
[DVD POWER MANAGER CHANGE-OVER]
• This mode is used to changed over DVD power ON/OFF for
decreasing of reception noise in the tuner mode.
Procedure:
1. Press the
button to turn the power ON.
I/1
[FUNCTION]
2. Press the
button to select "DVD".
3. Press the
button to turn the power OFF.
I/1
4. Press two buttons of
and
x
5. The message "DVD POWER ON" or "DVD POWER OFF"
will be displayed on the liquid crystal display, and DVD power
ON/OFF changed over in the tuner mode.
[COMPULSION INTERLACE]
• This mode is used to changed over video output into interlace.
Procedure:
1. Press the
button to turn the power ON.
I/1
[FUNCTION]
2. Press the
button to select "DVD".
3. Press two buttons of
X
and
4. Video output is changed over interlace.
[DVD TEST MODE GENERAL DESCRIPTION]
The Test Mode allows you to make diagnosis and adjustment easily
using the remote commander and monitor TV. The instructions,
diagnostic results, etc. are given on the on-screen display (OSD).
[TEST DISC LIST]
Use the following test disc on test mode.
TDV-520CSO (DVD-SL): PART No. J-2501-236-A
LUV-P01 (CD):
PART No. 4-999-032-01
TDV-540C (DVD-DL):
PART No. J-2501-235-A
Note: Do not use existing test disc for DVD.
28
[PLAY MODE]
[FUNCTION]
,
, and
simultaneously.
I/1
simultaneously.
I/1
[FUNCTION]
simultaneously.
[STARTING DVD TEST MODE]
1. Press the
button to turn the power ON.
I/1
[FUNCTION]
2. Press the
button to select "DVD".
3. Press the
button to turn the power OFF.
I/1
4. Press two buttons of
and
x
[VOLUME]
and
knob is turned clockwise.
5. The message "SERVICE IN" is displayed on the liquid crys-
tal display, and the Test Mode Menu is displayed on the mon-
itor screen as follows. (At the bottom of the menu screen, the
model name and revision number are displayed)
Test Mode Menu
0. Syscon Diagnosis
1. Drive Auto Adjustment
2. Drive Manual Operation
3. Mecha Aging
4. Emergency History
5. Mecha Error History
6. Version Information
7. Video Level Adjustment
Model
:BMZ-K7D
Revision :x.xx
6.
To execute each function, select the desired menu and press its
number on the remote commander (RM-Z20016).
7.
To release from test mode, press the
power off.
[OPERATING DVD TEST MODE]
0. SYSCON DIAGNOSIS
The same contents as board detail check by serial interface can be
checked from the remote commander operation.
On the Test Mode Menu screen, press
commander, and the following Check Menu will be displayed.
### Syscon Diagnosis ###
Check Menu
0. Quit
1. All
2. Version
3. EEPROM
4. GPIO
5. SD Bus
6. Video
0-0. Quit
Quit the Syscon Diagnosis and return to the Test Mode Menu.