11. Auto restarting operation
• When the power is restarted after a sudden power failure while in appliance operation, the mode before the
power failure is kept on the memory and the appliance automatically operates in the mode on the memory.
• The slide switch on the indoor unit of the appliance should be on the AUTO RESTART position in order that
the Auto restarting operation is available.
• Operation mode that is kept on the memory
— State of operation ON/OFF
— Operation mode/setting temp./selected airflow speed
— Sleep timer mode/remaining time of sleep timer

12. Forced operation

• To operate the appliance by force in case that the remote control is lost, the forced operation selection switch
is on the main unit of the appliance to operate the appliance in the standard conditions.
• The operation condition is set according to the outdoor temp. and intake air temperature as follows.
Outdoor temp.
over 24°C
21~24°C
18~21°C
below 18°C
Operating Mode
Cooling
Healthy Dehumidification
Intake air temp.
25°C
Intake air temp. < 25°C
Heating
Slide Switch of indoor unit
Dehumidification
Heating
-23-
FORCED
OPERATION
AUTO
RESTART
REMOTE
CONTROL
Setting speed of
Setting temp.
indoor fan
22°C
23°C
High speed
23°C
24°C
24°C