LG LS-J0761NL Service Manual page 33

Room air conditioner
Hide thumbs Also See for LS-J0761NL:
Table of Contents

Advertisement

Bundle the piping and drain hose together by
wrapping them with cloth tape over the range
within which they fit into the rear piping housing
section.
Drain hose
8. Reroute the pipings and the drain hose across the
back of the chassis.
9. Set the pipings and the drain hose to the back of
the chassis with the tubing holder.
Hook the edge of tubing holder to tap on chassis
and push the bottom of tubing holder to be
engaged at the bottom of chassis.
Tubing holder
Push
2
10. Indoor unit installation
Remove the spacer.
Ensure that the hooks are properly seated on the
installation plate by moving it left and right.
Press the lower left and right sides of the unit against the
installation plate until the hooks engage into their
slots(clicking sound).
Pipe
Vinyl tape(narrow)
Wrap with
vinyl tape(wide)
Piping for
passage through
piping hole
Hook
1
Connecting
cable
Drain hose
3) Connection of the pipes-Outdoor
1. Align the center of the pipings and sufficiently
tighten the flare nut by hand.
2. Finally, tighten the flare nut with torque wrench
until the wrench clicks.
When tightening the flare nut with torque wrench,
ensure the direction for tightening follows the
arrow on the wrench.
Capacity
(Btu/h)
7k, 9k
12k, 18k
Outdoor unit
-33-
Pipe Size[Torque]
GAS
LIQUID
3/8"[4.2kg . m]
1/4"[1.8kg . m]
1/2"[5.5kg . m]
1/4"[1.8kg . m]
Liquid side piping
(Smaller diameter)
Gas side
piping
(Bigger
diameter)
Torque wrench

Advertisement