8. Jet cool mode operation
• While in heating mode or Fuzzy operation, the Jet Cool key cannot be input. When it is input while in the
other mode operation(cooling, dehumidification, ventilation), the Jet Cool mode is operated.
• In the Jet Cool mode, the indoor fan is operated super-high speed for 30 min. at cooling mode operation.
• In the Jet Cool mode, the room temperature is controlled to the setting temperature, 18°C.
• When the sleep timer mode input while the Jet Cool mode operation, the Jet Cool mode has the priority.
• When the Jet Cool key is input, the upper/lower vane is reset to those of the initial cooling mode and then
operated in order that the air outflow could reach further.

9. Swing mode

9.1 Chaos swing mode of not fuzzy mode operation
• By the Chaos swing key input, the upper/lower vane automatically operates with the Chaos swing or it is fixed
to the desired direction.
< Cooling Mode >
Closed
Mode 8
Mode 7
Beginning
Mode 6
of cooling
Mode 5
Mode 4
Mode 3
< Cooling Mode >
Closed
Mode 8
Mode 7
Beginning
Mode 6
of cooling
Mode 5
Mode 4
Mode 3
< Cooling Mode >
Closed
Mode 8
Mode 7
Beginning
Mode 6
of cooling
Mode 5
Mode 4
Mode 3
Chaos swing of 7K, 9K Btu Series
135
8
Mode 2
Mode 1
Open
Chaos swing of 12K Btu Series
125
7
Mode 2
Mode 1
Open
Chaos swing of 18K Btu Series
125
7
Mode 2
Mode 1
Open
< Heating Mode >
Closed
Mode 8
Mode 7
Mode 6
Mode 5
Beginning
Mode 4
of heating
Mode 3
Mode 2
Mode 1
< Heating Mode >
Closed
Mode 8
Mode 7
Mode 6
Mode 5
Beginning
Mode 4
of heating
Mode 3
Mode 2
Mode 1
< Heating Mode >
Closed
Mode 8
Mode 7
Mode 6
Mode 5
Beginning
Mode 4
of heating
Mode 3
Mode 2
Mode 1