3. Connecting the Cable Between Indoor Unit and Outdoor Unit

1) Connect the cable to the Indoor unit.
Connect the cable to the indoor unit by connect-
ing the wires to the terminals on the control board
individually according to the outdoor unit connec-
tion.
(Ensure that the color of the wires of the outdoor
unit and the terminal No. are the same as those
of the indoor unit.)
• Inverter model
Terminals on the indoor unit
Color of Wires
Color of Wires
Terminals on the outdoor unit
CAUTION
If a power plug is not to be used, provide a circuit breaker between power source and
the unit as shown below.
1(L)
2(N)
3
BROWN
BLUE
GREEN/YELLOW
RED
BROWN
BLUE
GREEN/YELLOW
RED
2(N)
3
1(L)
Main power source
Air
Conditioner
CAUTION
The power cord connected to the indoor unit
should be complied with the following specifica-
tions
(Type H05VV-F approved by HAR or SAA).
The connecting cable connected to the indoor
and outdoor unit should be complied with the fol-
lowing specifications
(Type H07RN-F approved by HAR or SAA).
The length of the power supply cord should be over 1.8m
measured from the power supply cord entry of the cabinet
to the middle of the live pin of the plug.
Circuit Breaker
Use a circuit break-
er or time delay
fuse.
-34-
NORMAL
CROSS-SECTIONAL
AREA
2
7K,9K:1.0mm
2
12K:1.5mm
2
18K:2.5mm
NORMAL
CROSS-SECTIONAL
AREA
2
7K,9K:1.0mm
2
12K:1.5mm
2
18K:2.5mm