3) How to fix installation plate
The wall you select should be strong and solid enough to prevent
vibration
1. Mount the installation plate on the wall with four
type A screws. If mounting the unit on a concrete
wall, use anchor bolts.
Mount the installation plate horizontally by align-
ing the centerline using a level.
Type "A" screw
Weight
2. Measure the wall and mark the centerline. It is also
important to use caution concerning the location
of the installation plate-routing of the wiring to
power outlets is through the walls typically. Drilling
the hole through the wall for piping connections
must be done safely.
Left rear piping
80mm
Hole center
ø70mm
Left rear piping
"D"
Hole center
Installation Plate
Marking-off line
Thread
7k, 9k Btu
Right rear piping
50mm
ø70mm
18k Btu
Right rear piping
"C"
ø70mm
Left rear piping
C
B,D
Hole Center
For right rear piping and left rear piping, draw a
line in the direction of the arrow marked "C". The
meeting point of the two lines is the center of the
hole.
The position of the center of the hole.
Left holecore position
C
4) Drill a hole in the wall
• Drill the piping hole with a ø70mm hole core drill.
Drill the piping hole at either the right or the left with
the hole slightly slanted to the outdoor side.
Indoor
-28-
12k Btu
Right rear piping
D
A,B,C
C
A,B
A
C
A,B,D
D
Installation plate
Right holecore position
C
C
C
WALL
Outdoor

Advertisement

Table of Contents
loading