Download  Print this page

Kenmore 580.54351 Owner's Manual

Kenmore 580.54351 dehumidifier owner's manual
Hide thumbs

Advertisement

Owner's Manual
Manuel del Propietario
®
DEHUMIDIFIER
DESHUMIDIFICADOR
Model, Modelo 580.54351
J
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
www.sears.com

Advertisement

loading

  Related Manuals for Kenmore 580.54351

  Summary of Contents for Kenmore 580.54351

  • Page 1 Owner's Manual Manuel del Propietario ® DEHUMIDIFIER DESHUMIDIFICADOR Model, Modelo 580.54351 Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com...
  • Page 2 Installation ..........13 Safety Precautions ........3 Maintenance ..........14 Prior to Operation ........7 Instruction ........... 8 ESPANOL ........... 16 MASTER PROTECTION AGREEMENTS ..31 Electrical Safety .......... 9 SERVICE NUMBERS ....Back cover Operating Instructions ......11 Inside you will find many helpful hints on how to use and maintain your dehumidifier properly.
  • Page 3 Safety Precautions READ ALL INSTRUCTION BEFORE USING • To prevent injury to the user or other people and property damage,the following instructionsmust be followed. • Incorrectoperationdue to ignoring instructionswill cause harmor damage; the seriousnessis classified by the following indications. ! ,_, CAUTION This symbol indicatesthe possibilityof injury or damageto property only.
  • Page 4 Safety Precautions • It may cause electric shock or fire. • It may cause electricshock or fire. • Not grounding unit may cause electric shock. • Unpluggingthe unit may avoid • It may cause fire and electric • It may cause electric shock. electricshock or fire hazard.
  • Page 5 Safety Precautions CAUTION • Installation • It maycausefailureof applianceor • Otherwise,it may cause electric • Turning off the unit will save on performance deterioration. shockand damage. energy costs. • The dehumidifier must be • For proper operation,your • It is not designed to dehumidify dehumidifiershould be installed the entire house.
  • Page 6 Safety Precautions • Operation • The appearanceof the • Otherwise,it will cause property • Low temperatures could cause coils to frost. dehumidifiermay deteriorate, damage. change color, or developsurface flaws. • This could injure the pet or plant. • It is not sanitaryand couldcause •...
  • Page 7: Preparing For Operation

    Prior to Operation PREPARING FOR OPERATION 1. Plug the power cord in properly to a standard 3-slot grounding wall power outlet. 2. Do not plug any other appliance into the same wall receptacle as this unit. 3. Do not use an extension cord. 4.
  • Page 8 Instruction SYMBOLS USED IN THIS MANUAL This symbol alerts you to the risk of electric shock. This symbol alerts you to the possibility of personal injury property damage. FEATURES wiring regulations. This guide acts as a guide to help to explain product ARNING: This appliance...
  • Page 9 Electrical S afety WARNING: This appliance must be properly grounded. The power cord of this appliance is equipped with a three-prong grounding plug. To minimize the risk of electric shock, use the plug with a standard three-slot grounding wall power outlet. If the power outlet does not include a grounding slot, have a qualified electrician replace the outlet before you use the dehumidifier.
  • Page 10: Temporary Use Of An Adapter

    Electrical S afety TEMPORARY USE OF AN ADAPTER We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections, use only a UL-listed adapter, available from most local hardware stores. To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground terminal.
  • Page 11: Control Panel

    Operating Instructions ¸_i_i!_ii!_!!i!!_i!_iiii!ii!_! I_i;_,i_:i_!_i_i_!_i 'i' i!ili!i ! CONTROL PANEL Your dehumidifierhas a control panel containingan Auto shut-off indicator,a Fan Speed and Humidity Control. Auto shut off--- This light glows when the bucket fills or is missing. Fanspeed --- This switch controlsthe speed of the airflow. HumidityControl---This knob controlsthe moisturein the room.
  • Page 12: Automatic Shut-Off

    Operating Instructions AUTOMATIC SHUT OFF The dehumidifier has a water level control switch and will turn the unit off when the bucket is full, or when the bucket is removed or not replaced in the proper position. The bucket must be replaced in the proper position for the dehumidifier to work.
  • Page 13 Installation CHOOSING THE PROPER LOCATION FOR YOUR DEHUMIDIFIER • Use the dehumidifier in a • Use the dehumidifierin laundry • Use the dehumidifierto prevent basementto help prevent drying, bathing, and dishwashing moisturedamage where books areaswhich have excessive are stored. moisturedamage. moisture.
  • Page 14 Maintenance Your dehumidifieris designedto serve you year- round. It needs practicallyno attention. However, you shouldcheck your dehumidifierand inspectthe ElectricalShock Hazard coils annually. You may want Sears Parts & RepairCenter to • Disconnectpower supply cord from receptacle beforeperformingany maintenance. perform this annual checkup. (Cost of the inspection is the owner's responsibility.) •...
  • Page 15: Troubleshooting

    Maintenance TROUBLESHOOTING The dehumidifier may be operating abnormally when: Dehumidifier • Make sure the dehumidifier plug is pushed does not start completely into the outlet. • Check the house fuse or circuit breaker box and replace the fuse or reset the breaker. •...
  • Page 16 Your Home iiiiiiiiiiiiiiii_ iiiiiiiiiiiiiiiii For repair- in your home-of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter made it, no matter sold ....iiiiiiiiiiiiiiii_ iiiiiiiiiiiiiiiii For the replacement parts, accessories owner's manuals that you need to do-it-yourself....