DEFECTS:
Even when the warning
signal (the index of the
shutter speeds) turns to
red, the needle of the
meter does not rest
properly.
NOTE:
When the index turns to
red, the needle must drop
to the
side beyond the
(—)
"off" position.
CAUSES:
The
terminal plates (10029)
two
affixed to the variable resistor do
not make contact with the contact
piece (10032).
23102
SERVICING:
Set the ASA scale on the shutter
speed dial at ASA 100 and the
shutter speed at "B" and bend
(10029) with tweezers so as to
make it contact with (10032).