Specifications - Kenmore 795.71303.010 Service Manual

Bottom freezer refrigerator
Table of Contents

Advertisement

1. SPECIFICATIONS

1-1. DISCONNECT POWER CORD BEFORE SERVICING
IMPORTANT: Reconnect all grounding devices.
All parts of this appliance capable of conducting electrical current are grounded. If grounding wires, screws, straps, clips, nuts
or washers used to complete a path to ground are removed for service, they must be returned to their original position and
properly fastened.
1-2. IMPORTANT NOTICE
This information is intended for use by individuals possessing adequate background of electrical, electronic and mechanical
experience.
Any attempt to repair a major appliance may result in personal injury and property damage. The manufacturer or seller cannot
be responsible for the interpretation of this information, nor can it assume any liability in connection with its use.
1-3.
ELECTRICAL SPECIFICATIONS
Freezer temperature control (Middle setting)
Defrost Control ..............................................................................................................
Defrost Thermostat .......................................................................................................
Electrical Rating : 115VAC, 60Hz...................................................................................
Maximum Current Leakage ...........................................................................................
Maximum Ground Path Resistance ..............................................................................
Energy Consumption......................................................................................................
1-4. NO LOAD PERFORMANCE
Control Position: MID/MID
And Ambient of:
Fresh Food, °F........................................................
Frozen Foor, °F........................................................
Percent Running Time ..............................................
1-5. REFRIGERATION SYSTEM
Minimum Compressor Capacity Vaccum.............................
Minimun Equalized Pressure
@70°F..............................................................
@90°F..............................................................
Refrigerant R134a............................................................
Compressor...............................................................
.................................................................-6°F to +8°F
70°F
33°F to 41°F
Fresh Food, °F......................................................
-4°F to +4°F
Frozen Foor, °F.....................................................
25% - 35%
Percent Running Time ...........................................
1-6. INSTALLATION
21 in
Clearance must be provided at top, sides and rear of the
refrigerator for air circulation.
49 PSIG
56 PSIG
At Top.................................................................................
4.2 oz
At Sides..............................................................................
687 BTU/hr
At Rear...............................................................................
- 4 -
Automatic
46.4 °F
1-5 A
0.5mA
0.14 Ohms
466kWh/yr (Energy Star)
90°F
33°F to 41°F
-4°F to +4°F
45% - 60%
2 in
2 in
2 in