5. GENERATOR
USE
m
To prevent electrical shock from faulty appliances, the generator
should be grounded.
Connect a length of heavy wire between the ground
terminal and the ground source.
CAUTION:
l
Limit operation
requiring maximum power (EB3000 : 3.0 kVA, EB4000 :
4.0 kVA) to 30 minutes.
For continuous
operation,
do not exceed the rated power of 2.8 kVA
(EB3000) and 3.8 kVA (EB4000).
In either
case, the total
wattage of all appliances connected
must be
considered.
l
Do not exceed the current limit specified for any one receptacle.
l
Do not connect
the generator to a household
circuit.
This could cause
damage to the generator or to electrical appliances in the house.
Auto-throttle
system
With the switch in the AUTO position, engine speed is automatically
reduced
to an idle when all loads are turned off or disconnected. When appliances are
turned on or reconnected, the engine resumes the rated speed. At OFF, the
auto-throttle
system does not operate.
NOTE:
l
AUTO is recommended to minimize fuel consumption.
l
The auto-throttle
system will not respond to electrical loads of less than 1
ampere.
l
The system is not effective
for use with
appliance
that require only
momentary
power. To avoid extended warm-up periods, keep the switch
OFF until the engine reaches operating temperature.
11