EASY VALVE appliCatiON aND OpEratiON
Remove complete balloon unit
Beware of hot surface!
after filling a balloon do not
touch any parts of the filling
chamber or of the cap until
they have cooled down.
Beware of hot surface!
Never leave the filling chamber on top
of the exhaust vent of the VOLCANO
as long as the heater is on, except when
filling the balloon. Non-observance can
lead to an overheated filling chamber,
which might burn one's fingers.
Detach the valve balloon from the fil-
ling chamber. When you do so, the
valve is automatically closed so that
the vapors in the balloon cannot es-
cape.
Detach valve balloon from filling chamber
attach the mouthpiece to the valve
balloon and allow it to lock in place.
Attach the mouthpiece
to the valve balloon
to inhale, put the mouthpiece to your
lips and lightly press against the
mouthpiece with your lips. By doing
so, the valve opens and the vapors
can be inhaled from the balloon. as
soon as you remove the pressure
from the mouthpiece, the valve auto-
matically closes.
18
EASY VALVE appliCatiON aND OpEratiON
Press mouthpiece against lips to inhale
When the content of the bal-
loon is almost used up, you
can empty the balloon com-
pletely by pulling it tight.
EASY VALVE ClEaNiNG aND maiNtENaNCE
EASY VALVE valve balloon with
mouthpiece
the EASY VALVE valve balloon with
mouthpiece does not require any main-
tenance and should be replaced re-
gularly with a new valve balloon with
mouthpiece for hygienic reasons. For
the same reasons, a valve balloon
with mouthpiece should not be used
by several persons at the same time.
Filling chamber with cap
Before disassembling, allow the filling
chamber and the cap to cool down.
Stretch balloon
tight
these parts should be cleaned regu-
larly to guarantee proper functioning
and a clean taste. For hygienic reasons
cleaning should also be done when the
device is used by other persons. For
manual cleaning, use spirit (ethyl alco-
hol) and paper or cotton towels only.
Filling chamber and cap are easily
disassembled and reassembled within
seconds. Filling chamber and cap
parts may also be cleaned in a dish-
washer. Screens, cap ring and clips
are too small for this and might get lost
in a dishwasher. Before assembling
allow all parts to dry properly.