Panasonic CS-XE12PKUA Submittal Data
Panasonic CS-XE12PKUA Submittal Data

Panasonic CS-XE12PKUA Submittal Data

Wall mounted air conditioners
Hide thumbs Also See for CS-XE12PKUA:

Advertisement

Quick Links

Split System Submittal Data
Indoor: CS-XE12PKUA Outdoor: CU-XE12PKUA
Wall Mounted Air Conditioners
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:

General Data

Power (V/P/Hz)
Circuit Ampacity (A)
Fuse Size, Max.(A)
Compressor
No. Used
Output Power (W)

Outdoor Unit

Fan Type
Motor Type
Output Power (W)
Airflow (CFM)
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area (sq.ft.)

Indoor Unit

Fan type
No. Speeds
RPM (High)
Motor Output (w)
CFM (QLo/Lo/Me/Hi/SHi)
Indoor Sound Rating (Hi) (dB-A)
Coil Type
Fin Type - Pipe Type
Rows - F.P.I
Face Area (sq.ft)
Drain Connection Size (in.)
Refrigerant
Lbs. - R410a (Outdoor Unit)
Control
Connection
Line Length, Max (ft.)
Lift Difference, Max (ft.)
Line Size (in. O.D. Discharge)
Line Size (in. O.D. Suction)

Dimensions (HxWxD)

Indoor Unit (Crated) (in.)
Indoor Unit (Uncrated) (in.)
Outdoor Unit (Crated (in.)
Outdoor Unit (Uncrated) (in.)

Weight

Net, Indoor (lbs.)
230/208/1/60
15
20
DC Twin Rotary
1
700
Propeller
DC Motor ( 8 poles )
40
1555
Aluminum (Blue Coated)
Corrugated Fin
18
5.99
Cross Flow
5
1350
40
170/240/390/530/550
44
Aluminum Fin & Copper Tube
Slit Plate - Inner Rifled
21
2.45
3/4
R410A
2.54
Electronic Expansion Valve
Flare
66
49
1/4"
1/2"
11-7/8"x37-13/16"x14-3/8"
11-5/8"x34-9/32"x10-1/16"
29-11/32"x41-5/16"x18-1/8"
27-3/8"x34-15/32"x12-5/8"
24
Approval:
Date:
Construction:
Unit#:
Drawing#:
Shipping, Indoor (lbs.)
Net, Outdoor (lbs.)
Shipping, Outdoor (lbs.)

Performance Data @ ARI Standard Conditions (230/208V)

Cooling

Total Capacity (BTU/H)
Sensible Capacity (BTU/H)
Latent Capacity (BTU/H)
SEER
Dehumidification (Pints/H)
Amps (A)
Power Inputs (W)
Outdoor Sound Rating (dB-A)

Heating

Total Capacity (BTU/H)
HSPF
Amps (A)
Power Inputs (W)
Outdoor Sound Rating (dB-A)

Features

Wireless Remote Controller
Wired Remote Controller ( CZ-
RD516C )
Controls
Remote Control
Temperature Control
Air Louver, Horizontal
Air Louver, Vertical
Power Failure Automatic Restart
Self-Diagnosis
Air Filter

Operating Range

Indoor Air Intake Temp
Cooling (Max)
90F DB/74F WB
Cooling (Min)
60F DB/52F WB
Heating (Max)
86F DB/-F WB
Heating (Min)
60F DB/-F WB
26
97
108
11,500 (2,800-14,000)
10,120
1,380
25.5
2.3
4.2/3.8
800 (150-1,050)
49
13,800 (3,000-23,000) (Max at 5F
12,500)
12.0
5.8/5.2
1,150 (150-2,100)
49
Standard
Optional
Microprocessor
LCD Wireless Type
IC Thermostat
Manual
Automatic
Built-In
Built-In
Washable, One-touch
Outdoor Air Intake Temp
115F DB/79F WB
0F DB/-F WB
75F DB/64F WB
0F DB/-2.2F WB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CS-XE12PKUA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Panasonic CS-XE12PKUA

  • Page 1 Split System Submittal Data Indoor: CS-XE12PKUA Outdoor: CU-XE12PKUA Wall Mounted Air Conditioners Job Name: Approval: Location: Date: Engineer: Construction: Submitted to: Unit#: Submitted by: Drawing#: Reference: General Data Power (V/P/Hz) 230/208/1/60 Circuit Ampacity (A) Fuse Size, Max.(A) Compressor DC Twin Rotary No.
  • Page 2: Indoor Dimensions

    Indoor Dimensions 5. Dimensions Indoor Unit Outdoor Dimensions Outdoor Unit Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 http://www.panasonic.com/aircon...

This manual is also suitable for:

Cu-xe12pkua

Table of Contents