Circula tor Blow e r Spe e ds
Spe e d
Low
Medium Low
Medium
High
Common/Neutral
Blower Heat Off Delay Timings
The integrated control module provides a selectable heat
off delay function. The heat off delay period may be set to
60, 90, 120, 180 seconds using the DIP switches or jumper
provided on the control module. The delay is factory shipped
at 90 seconds but may be changed to suit the installation
requirements and/or homeowner preference. Refer to the
following figure for switch positions and corresponding de-
lay times.
46
Rev. 0

PRODUCT DESIGN

W ire Color
Red
Orange
Blue
Black
W hite
DIP Switches
60
Second
ON
Delay
ON
90
Second
OFF
Delay
ON
120
Second
ON
Delay
OFF
180
Second
OFF
Delay
OFF
Heat Off Delay Switches
Jumper
180
90
180
90
180
90
180
90