Product Identification - Amana GUCA045AX30 Service Instructions Manual

40" 90% condensing gas furnaces guca, gcca & accessories
Table of Contents

Advertisement

Connection for
Fresh Air Intake
Pipe to Furnace
Connection for
Vent/Flue Pipe
Tee
from Furnace
Pipe to Furnace
HVCK Installation
Concentric Vents Kits HVCK and VCVK
are suitable for use with the following
Amana 90% efficient furnace products:
CONCENTRIC VENT KIT
Used On Models
GUCA
GCCA
This kit is not certified for, and must not
be applied to any furnace not listed in the
above table.

PRODUCT IDENTIFICATION

ACCESSORIES
Horizontal
(HCVK)
Combustion
Air Intake Pipe
Vent/Flue Termination
with Tee
Seal Penetration
12" Minimum Above
with Caulking
Grade or Highest
Anticipate Snow Level
Wall Thickness
3/4" Minimum
13 3/4" Maximum
CONCENTRIC VENT CONVERSION KIT
Vertical
(VCVK)
Combustion Air
Intake Pipe
Roof Thickness
3/4" Minimum
22" Maximum
Interior Section
of Concentric Vent Assembly
Must Be Adequately
Secured and Supported
Sanitary Tee
Connection for
Fresh Air Intake
Pipe to Furnace
VCVK Installation
Vent/Flue
Termination
(Tee, Pipe, & 2" to 4" Reducer)
12" Minimum Above
Roof or Highest
Anticipated Snow Level
Seal Penetration
with Flashing
and Caulking
Outside
Inside
Connection for
Vent/ Flue Pipe
From Furnace
13
Rev. 0