Emerson VSG Manual page 51

Single screw bare shaft compressor
Hide thumbs Also See for VSG:
Table of Contents

Advertisement

DISCHARGE MANIFOLD INSTALLATION
A) Install (2) guide rods to position the discharge
manifold. Install a new manifold gasket and
the discharge manifold. Install the dowel pins
and bolts, tighten manifold bolts to the recom-
mended torque value.
B) On VSG 751-2101 and VSSG 291-601 compres-
sors install the discharge spool or elbow be-
tween the discharge manifold and oil separator
with new gaskets. When installing the discharge
elbow tighten the bolts to the correct torque on
the manifold flange first before tightening the
separator flange bolts. Install the drain plug in
the bottom of the discharge manifold.
C) On VSG 301-701 compressors install the bolts
in the discharge flange. Install the drain plug in
the bottom of the discharge manifold.
D) Install both command shaft assemblies and
control actuators.
SLIDE VALVE GEAR AND RACK INSPECTION
A) Remove the discharge manifold.
B) Check rack to rack clamp and rack clamp spacer
clearance on all four slide valves.
TABLE 4.1
RACK CLEARANCE VALUES
MEASUREMENT
Rack to clamp.
Rack to clamp spacer.
C) Check torque of socket heat cap screws.
D) Check for excessive movement between the
slide valve rack shafts and the rack. The jam nuts
on the end of the slide valve rack shaft should be
tight.
E) Check for loose or broken roll pins in gears.
Service
CLEARANCE
0.005 to 0.010"
0.003 to 0.005"
F) Look for any excessive wear on all moving parts
and replace the worn parts.
G) Reassemble the manifold and discharge elbow.
REMOVAL OF CAPACITY OR VOLUME CROSS
SHAFTS
A) Remove the discharge manifold.
B) To remove the capacity or volume ratio slide
valve racks, remove the two jam nuts and lock
washers (361) securing the rack (316) to the slide
valve shafts. The racks can now be pulled off the
slide valve shafts. Repeat the procedure for the
remaining pair of slide valve racks.
51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents