Step 3 - Ground the Generator
Failure to properly ground this generator can result in electrocution.
Ground this generator by tightening the grounding nut against a grounding wire as previously illustrated in Figure 3. A generally acceptable
grounding wire is a No. 12 AWG (American Wire Gauge) stranded copper wire. The other end of this grounding wire should be connected to a
copper or brass grounding rod that is driven into the earth. Grounding codes can vary by location. Contact a local electrician for information on
grounding regulations for your area.
STARTING THE GENERATOR
STOP!
Before starting this generator, confirm that all the steps in the section titled, "Preparing the Generator for Use," of this manual have been
correctly completed. If unsure about how to perform any of these steps, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time for
customer service.
Disconnect all electrical loads from this generator before attempting to start.
Step 1
Open fuel supply source.
Step 2
Turn ENGINE SWITCH at ON position.
Step 3
Move Choke Lever to CHOKE position.
Step 4
For recoil start: Pull the STARTER GRIP slowly until resistance is felt and then pull rapidly. After the engine started, return the STARTER
GRIP gently to prevent damage to the starter or housing. DO NOT allow the starter grip to snap back. Return it slowly by hand.
Step 5 Turn the CHOKE LEVER to RUN position