Electrical Adjustment
Grp / No. Item
255
(LX505) Fan Start/Cooling Setting
0
Fan1 Initial Volt
1
Fan2 Initial Volt
2
Fan3 Initial Volt
3
Fan4 Initial Volt
4
Fan5 Initial Volt
5
Fan6 Initial Volt
6
Fan7 Initial Volt
8
Cooling Time
10
Temp Error Cooling Time
11
OnStart Cooling Start Threshold
12
After shutdown cooling
256
Fan Lamp Voltage Down Setting
0
Lamp Voltage
1
Lamp Vol Threshold
2
Fan1 Speed Gain
3
Fan2 Speed Gain
4
Fan3 Speed Gain
5
Fan4 Speed Gain
257
Fan Setting at Dimmer
0
Dimmer Average Check Period
259
Fan Air Pressure Setting
0
Press Source Range Low
1
Press Source Range High
6
Press Fan Add Range High
7
Press Fan Add Range Low
8
Press Fan Add Range High
9
Press Fan Add Range Low
10
Press Fan Add Range High
11
Press Fan Add Range Low
12
Press Fan Add Range High
13
Press Fan Add Range Low
17
Temp A Warning Normal Highland Temp A (Room) to judge the Temp Error at Normal/Highland
18
Temp B Warning Normal Highland Temp B (Lamp) to judge the Temp Error at Normal/Highland
19
Temp CB Warning Normal Hiland
20
Temp A Warning Eco Highland
21
Temp B Warning Eco Highland
22
Temp C Warning Eco Hilghand
260
Auto Calibration (Common)
0
Execute Calibration
1
Loop Count
2
Auto Status
3
AutoWait
4
CHECK - Tolerance
5
Time out wait
261
Auto Calibration (RGB)
0
OFFSET AREA H START
1
OFFSET AREA V START
2
GAIN AREA H START
3
GAIN AREA V START
4
Image AREA H WIDTH
5
Image AREA V HEIGHT
6
OFFSET Target
7
OFFSET Tolerance
8
GAIN Target
9
GAIN Tolerance
10
Image Level Tolerance
LX505/605 Service Manual
020-000233-01 Rev.1 (12-2009)
Function
Fan Start Voltage (0.1V)
Coolong Time Setting (x30 sec.) 1: 30 3: 90 15: 450
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
Cooling Operation after Shut Down (0: No, 1: Yes)
Current Lamp Voltage (0.1V) (Read only)
Threshold Voltage (0.1V)
Fan Speed Ad Gain (0.1V)
Dimmer Average Check Period (sec.)
0: 10, 1: 30, 2: 60, 3: 90......10:300
Pressure Sensor Control Range (AD)
Add value of Fan control for Lamp Fan at Normal
Add value of Fan control for other fans at Normal
Add value of Fan control for Lamp Fan at Eco
Add value of Fan control for other fans at Eco
Temp C (Panel) to judge the Temp Error at Normal/Highland
Temp A (Room) to judge the Temp Error at Eco/Highland
Temp B (Lamp) to judge the Temp Error at Eco/Highland
Temp C (Panel) to judge the Temp Error at Eco/Highland
Execute Calibration when the Value is changed. (For PC White
100%)
Max Times of Calibration
Calibration Log (Read only)
0: Calibration End Correctly 1: On Adjusting 9: Calibration
Error
Waiting time
Tolerance of Offset
Wait Time until Time out [sec.]
PW392-AFE MDL <10bits>
Black Level Acq. Area H Start
Black Level Acq. Area V Start
White Level Acq. Area H Start
White Level Acq. Area V Start
Black/White Level Area Width
Black/White Level Area Height
Black Level Adj target
Black Level Adj telerance
White Level Adj target
White Level Adj telerance
Acq. Image Level Adj Tolerance
Range
0-255
0-255
0-255
0-255
0-255
0-255
0-255
1-15
1-15
0-100
0-1
0-255
30-90
0-1500
0-1500
0-1500
0-1500
0-10
0-1023
0-1023
0-5000
0-5000
0-5000
0-5000
0-5000
0-5000
0-5000
0-5000
0 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 1
1 - 30
0 / 1 / 9
1 - 20
1 - 255
1 - 255
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 1023
1 - 1023
0 - 1023
1 - 1023
1 - 255
-57-
Initial
Note
45
45
70
45
65
70
55
3
3
38
1
---
30
0
10
10
10
10
1
661
398
10
30
20
40
5
15
20
40
48
73
67
48
71
65
* Auto calibration
0
8
0
3
4
20
975
500
25
500
13
9
20
1
955
1
8