Contents Blue Seal Gas Target Top Target Top - 900mm. Introduction ..................... 2 Specifications ................... 3 Model Numbers Covered in this Specification General Gas Supply Requirements Gas Connection Dimensions ....................5 Weight Installation ....................9 Installation Requirements Unpacking Location Clearances...
Introduction We are confident that you will be delighted with your BLUE SEAL TARGET TOP, and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new Blue Seal Target Top, there are two important things you can do.
Specifications Model Numbers Covered in this Specification G57 - LS Gas Target Top, 900mm wide Hob on Leg Stand. G57 - B Gas Target Top, 900mm wide Bench Mount Hob. G57 - CB Gas Target Top, 900mm wide Hob with Base Cabinet.
Specifications Gas Connection Bench Models Gas supply connection point is located 130mm from right hand side of appliance, 32mm from rear, 55mm from floor and is entered from beneath appliance. An optional underside connection is available. All Other Models: Gas supply connection point is located 130mm from right hand side of appliance, 32mm from rear, 655mm from floor and is entered from beneath appliance.
Check equipment and parts for damage. Report any damage immediately to carrier and distributor. Ensure all 4 adjustable feet are fitted with the protruding centre screw. (Not fitted on G57 - RB Models).
All Models are delivered completely assembled. No further assembly is required, with exception of Leg Stand Model (G57-LS), this will require assembly. Refer to Fitting of Adjustable Feet / Rear Rollers to Leg Stand Units' information overleaf for assembly instructions.
Installation Fitting Leg Stand to Target Top Caution To prevent equipment damage and risk of injury, remove all castings, fire bricks and other removable items prior to fitting leg stand. Remove centre casting from target top using casting removal tool. Remove 2 half plate castings and all fire bricks from target top.
Gas Connection NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN AUTHORISED PERSON. Blue Seal Target Tops do not require an electrical connection, as they function totally on gas supply only. It is essential that gas supply is correct for target top to be installed and that adequate supply pressure and volume are available.
Installation Check gas operating pressure is as shown in 'Specifications' section. NOTE: Measure Burner operating pressure at target top hob manifold test point with target top burner (Inner and outer ring) operating at full setting. Turn ‘Off’ mains gas supply and bleed gas out of appliance gas lines.
/ operator. Blue Seal target tops have been designed to provide simplicity of operation and 100% safety protection. Improper operation is almost impossible, however bad operation practices can reduce life of target top and produce a poor quality product.
Operation Lighting Pilot Burner Remove centre casting with casting removal tool. Push-in control knob and rotate anti-clockwise to PILOT position. With control knob depressed, manually light pilot burner located in front of main burner. Hold in control knob for approximately 10 to 15 seconds, then release. The pilot burner should remain alight.
Cleaning and Maintenance General Caution Always turn ‘Off’ gas supply before cleaning. This appliance is not water proof. Do not use water jet spray to clean interior or exterior of this appliance. Clean Target Top regularly. A clean appliance looks better, will last longer and will perform better. Carbonised grease on cooking surfaces will hinder transfer of heat from cooking surface to food.
Cleaning and Maintenance c. DO NOT use water on castings while they are still hot as cracking may occur. Should it be necessary to clean castings, allow castings to cool and then remove for cleaning. Clean using a soft cloth moistened with a mild detergent and hot water solution and a scrubbing brush. Dry thoroughly with a dry cloth.
Fault Finding This section provides an easy reference guide to more common problems that may occur during operation of your equipment. The fault finding guide in this section is intended to help you correct, or at least accurately diagnose problems with your equipment. Although this section covers the most common problems reported, you may encounter a problem not covered in this section.
Gas Conversion and Specifications Conversion Procedure Caution Ensure Appliance is isolated from gas and electrical supplies before commencing servicing. NOTE: These conversions should only be carried out by qualified persons. All connections must be checked for leaks before re-commissioning appliance. ...
Gas Conversion and Specifications Pilot Burner Main Burner NOTE: Ensure pilot burner and thermocouple are Ignition Port correctly located and pilot burner aligns with Thermocouple main burner ignition port. (Refer to figure 2± 2.0 18± 2.0 opposite for correct fitting and alignment dimensions).
Gas Conversion and Specifications Gas Specifications - Non CE Only (Australia / New Zealand): Natural Gas LP Gas (Propane) Main Burner Injector (Inner Ring) Ø 1.70mm Ø 1.10mm Main Burner Injector (Outer Ring) Ø 2.60mm Ø 1.55mm Pilot Burner Injector 0.35 0.25 Burner Aeration Screw X (Inner)
Replacement Parts List Replacement Parts List IMPORTANT: Only genuine authorized replacement parts should be used for servicing and repair of this appliance. Instructions supplied with parts should be followed when replacing components. For further information and servicing instructions, contact your nearest authorized service branch (contact details are as shown on reverse of front cover of this manual).