Charcoal Filter; Resetting The Charcoal Filter Operating Hours Counter; Disposing Of The Charcoal Filter - Miele DA 6296 W Operating And Installation Instructions

Cooker hood
Hide thumbs Also See for DA 6296 W:
Table of Contents

Advertisement

Charcoal filter

If the cooker hood is connected for
recirculation, a charcoal filter must be
inserted in addition to the grease filter.
This is designed to absorb cooking
odours.
Replacement charcoal filters can be
obtained from your Miele retailer or via
the internet at www.miele-shop.com.
See back cover for contact details, and
"Technical data" for type and reference
number.
Fitting and replacing the charcoal
filter
 Before fitting or replacing a charcoal
filter, the grease filters must first be
taken out (see previous section for
instructions on how to do this).
 Take the charcoal filter out of its
packaging.
 Insert the charcoal filter into the back
of the charcoal filter frame, then push
up into the frame at the front.
 Replace the grease filters.
 When fitting for the first time, activate
the operating hours timer (see
"Operation").
Cleaning and care
When to change the charcoal filter
 Always replace the charcoal filter
when it no longer absorbs kitchen
odours effectively.
It should, however be replaced at
least every 6 months.
The charcoal filter operating hours
counter  will light up to remind you to
change the charcoal filter regularly.
 The charcoal filter operating hours
counter needs to be activated before
using for the first time (see
"Operation").
Resetting the charcoal filter
operating hours counter
After changing charcoal filter, the
operating hours counter needs to be re-
set.
 To do this, with the fan switched on,
press the operating hours control
 once, then press it again and
hold it for approx. 3 seconds until
only the 1 is flashing. The charcoal
filter symbol  will go out.
If you want to clean the charcoal filter
before the operating hours counter has
reached its maximum:
 Press the operating hours control
 once, then press it again and
hold it for approx. 6 seconds until
only the 1 is flashing.

Disposing of the charcoal filter

 Used charcoal filters can be disposed
of with the normal household waste.
29