Operation (Automatic and Manual modes)
Activating/changing the charcoal
filter saturation indicator
The charcoal filter is required for the
recirculation mode.
The filter saturation indicator for the
charcoal filter must be activated once
and should be set to match your
cooking habits.
 Press the On/Off button  to turn the
blower off.
 Press the "" symbol and the filter
saturation indicator  at the same
time.
The charcoal filter symbol  and one of
the blower power level indicators will
flash.
The indicators 1 to B show the current
time setting:
Indicator 1 ............................ 120 hours
Indicator 2 ............................ 180 hours
Indicator 3 ............................ 240 hours
Indicator B .......................... deactivated
 Press the "" symbol for a shorter
operating time, or the "" symbol to
select a longer operating time.
 Confirm the selection by pressing the
filter saturation indicator .
All the indicator lights go out.
If the new setting is not confirmed
within 4 minutes, the hood reverts to
the previous setting.
22
Checking the filter saturation
indicator
Before the set operating time has run
out, you can check what percentage of
the time has elapsed.
 Press the On/Off control  to turn the
blower on.
 Press and hold the filter saturation
indicator .
- Once, to check the grease filter
operating time. The grease filter
symbol  lights up.
- Twice, to check the charcoal filter
operating time. The charcoal filter
symbol  lights up.
One or more of the blower power level
indicators will flash simultaneously.
The number of flashing indicators
shows the elapsed operating time as a
percentage.
Indicator 1 .................................... 25%
Indicators 1 and 2 ......................... 50%
Indicators 1 to 3 ........................... 75%
Indicators 1 to B ......................... 100%
The number of elapsed operating
hours remains stored in memory when
the ventilation hood is turned off or if
there is a power outage.