Wiring Diagrams Indoor Unit - Haier HSU-18,22HVA103/R2(DB) Service Manual

V series wall mounted type
Table of Contents

Advertisement

10.2 Wiring Diagrams
Indoor Unit
HSU-18HVA103/R2(DB)
Y/G
CN17
C0N15
C0N21
2
1
TO OUTDOOR UNIT
NOTES:
THE PARTS OF DOTTED ARE OPTIONAL
HSU-18,22HVA103 /R2(DB)
INDOOR UNIT DIAGRAM
LOUVER
FAN MOTOR
MOTOR
C ON12
CN7
CN3
CN4
CN16
C0N14
BR
3
POWER SUPPLY
LOUVER
MOTOR
EMERGENCY
SWITCH
CN11
CN8
CN9
CN5
CN5-1
BL
134
Appendix
0010551718
LOUVER
MOTOR
LOUVER
MOTOR
DISPLAY
RECEIVER
BOARD
W:
WHITE
B:
BLACK
R:
RED
BL: BLUE
BR: BROWN
Y/G: YELLOW
/GREEN
Domestic air conditioner

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hsu-18hva103/r2(db)Hsu-22hva103/r2(db)