■ Lamp Replacement

How to check lamp used time
The LAMP REPLACE indicator will light when the total
lamp used time reaches 3,000 hours. This is to indi-
cate that lamp replacement is required.
The total lamp used time is calculated by using the
below expression;
=
T
Total lamp used time
T
eco: used time in the Eco mode
T
normal: used time in the Eco mode
You can check the lamp replace counter following to
below procedure.
1
Press and hold the POWER ON-OFF button on the
projector or the remote control unit for more than 20
seconds.
This projector uses a high-pressure lamp which must be handled carefully and properly. Improper
handling may result in accidents, injury, or create a fire hazard.
Lamp lifetime may differ from lamp to lamp and according to the environment of use. There is no
guarantee of the same lifetime for each lamp. Some lamps may fail or terminate their lifetime in a
shorter period of time than other similar lamps.
If the projector indicates that the lamp should be replaced, i.e., if the LAMP REPLACE indicator lights
up, replace the lamp with a new one IMMEDIATELY after the projector has cooled down.
( Follow carefully the instructions in the Lamp Replacement section of this manual. ) Continuous use
of the lamp with the LAMP REPLACE indicator lighted may increase the risk of lamp explosion.
A Lamp may explode as a result of vibration, shock or degradation as a result of hours of use as its
lifetime draws to an end. Risk of explosion may differ according to the environment or conditions in
which the projector and lamp are being used.
IF A LAMP EXPLODES, THE FOLLOWING SAFETY PRECAUTIONS SHOULD BE TAKEN.
If a lamp explodes, disconnect the projector's AC plug from the AC outlet immediately. Contact an
authorized service station for a checkup of the unit and replacement of the lamp. Additionally, check
carefully to ensure that there are no broken shards or pieces of glass around the projector or coming out
from the cooling air circulation holes. Any broken shards found should be cleaned up carefully. No one
should check the inside of the projector except those who are authorized trained technicians and who are
familiar with projector service. Inappropriate attempts to service the unit by anyone, especially those who
are not appropriately trained to do so, may result in an accident or injury caused by pieces of broken
glass.
+
T
eco
normal x (1.5)
LAMP HANDLING PRECAUTIONS
2
The projector used time and lamp used time will be
displayed on the screen briefly.
Counter
Projector
Lamp
Normal
Total lamp used time
-5-
Projector used time
525H
100H
Eco
375H
Total
525H