Sanyo PLV-Z2 Service Manual page 20

Hide thumbs Also See for PLV-Z2:
Table of Contents

Advertisement

■ Optical Parts Disassemblies
7.
LOCATIONS IN OPTICAL UNIT
When mounting or assembling the optical parts in the optical unit, the parts must be mounted specified location as shown
in figure below.
Cut Face
12
6
17
Marking
Marking
11
7
13
1
2
18
9
Cut Face
11
5
15
16
14
10
Key No. Description
1
Lens (Condenser G)
4
2
Lens (Condenser R)
3
Prism Beam Splitter (PBS)
3
4
Condenser Lens (Out)
5
Condenser Lens (B)
6
Relay Lens (In)
7
Relay Lens (Out)
8
Integrater Lens (In)
9
Integrater Lens (Out)
10
Mirror (R)
11
Mirror (B)
12
Optical Filter (R, G)
8
13
Optical Filter (UV Cut)
14
Polarized Grass (IN/R)
15
Polarized Grass (IN/B)
16
Polarized Grass (IN/G)
17
Di-chroic Mirror (G)
18
Di-chroic Mirror (R)
-20-