Protections - Sanyo PLV-Z2 Service Manual

Hide thumbs Also See for PLV-Z2:
Table of Contents

Advertisement

■ Protections

This projector is equipped with the following protections to operate in safety. If the abnormality occurs
inside the projector, it will turn off the projector by operating one of the following protections.
■ FUSE FOR CIRCUIT PROTECTION
The fuse is located on the ass'y-Inlet. When either the
LAMP indicator or the READY indicator is not illuminated,
fuse may be opened. Check the fuse as following steps.
1. Remove the ass'y-Inlet following to "Mechanical
Disassemblies".
2. Remove the fuse from fuse holder.
3. Check the resistance of fuse by using the tester.
To install the fuse, take reversed step in the above.
It should be used the specified fuse as parts list.
■ OVERHEATING PROTECTION
The temperature monitor system is provided to prevents damage of component parts inside the pro-
jector from overheat.
■ Thermostat Switch: SW902
This function (thermostat switch SW902) will not operate,
while the temperature monitor is operating normally. If it
has operated, it needs to be reset manually. Disconnect
the AC cord first and investigate the cause of overheating.
After servicing, reset the thermostat switch (SW902) as
shown in a figure.
(The temperature monitor system )
-11-
Ass'y Inlet
Fuse
SW902

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents