SECTION 5

5-1 PREPARATION

REQUIRED TEST EQUIPMENT
EQUIPMENT
Output voltage
DC power supply
Current capacity
Measuring range
Frequency range
RF power meter
Impedance
(terminated type)
SWR
Frequency range
Frequency accuracy : ±1 ppm or better
Frequency counter
Sensitivity
Frequency range
FM deviation meter
Measuring range
Digital multimeter
Input impedance
TRIMMER ADJUSTMENT
When you adjust the contents on page 5-4 or 5-8, TRIMMER ADJUSTMENT, the optional CS-F3
(Rev. 3.0 or later) and OPC-478
• STARTING TRIMMER ADJUSTMENT
Turn ON power to the transceiver, connect a computer to the [SP] jack using the optional OPC-478 CLONING CABLE, then
start up the "ADJUST" program in CS-F3.
• STARTING THE PROGRAM
q Boot up DOS.
w Insert the CS-F3 backup disk into drive A.
e Type the following to start up the program:
ADJ>ADJUST [Enter]
• The adjustment screen appears after reading set data
from the transceiver.
r After the adjustment screen appears, set or modify the
data as desired.
NOTE:
When the EEPROM (IC7) is replaced or the transceiver displays an error message and beeps, the following oper-
ation is necessary before starting the ADJUSTMENT.
1. Download the programmed frequency data using the CS-F3
exact same version of the transceiver, then save it. (See the instructions for detailed operation.)
2. Return to DOS.
3. Copy the saved frequency data into the "ADJ" directory as follows:
A>COPY [file name].ICF A:\ADJ [ENT]
4. Connect the transceiver in which the EEPROM has been replaced, using the OPC-478 CLONING CABLE.
5. Change the directory to "ADJ", and type as follows:
A>CD ADJ [ENT]
A>ADJ>EEPROM [file name].ICF 1* [ENT]
When cloning is successful, the transceiver displays "CL GOOD".
*RS-232C port number. You have to type "A>EEPROM [file name].ICF 2" when the port number is set to "2". This setting
can be confirmed in the SETUP window while CS-F3 is running.

ADJUSTMENT PROCEDURES

GRADE AND RANGE
: 9.6 V DC
: 5 A or more
: 1–10 W
: 120–500 MHz
: 50 Ω
: Less than 1.2 : 1
: 0.1–500 MHz
: 100 mV or better
: DC–500 MHz
: 0 to ±5 kHz
: 10 MΩ/V DC or better
are required.
CLONING CABLE
EQUIPMENT
Audio generator
Frequency range
Output level
Attenuator
Power attenuation
Capacity
Standard signal
Frequency range
generator (SSG)
Output level
DC voltmeter
Input impedance
Oscilloscope
Frequency range
Measuring range
AC millivoltmeter
Measuring range
A:\>CD ADJ
A:\>ADJ>ADJUST
***** Trimmer Control Software for IC–F3 Series *****
A/D 1 (VIN)
171 : ABh 10.729V
D/A 1 (REF)
120 : 78h
A/D 2 (REMOTE) 255 : FFh
5.000V
D/A 2 (MODE)
131 : 83h
A/D 3 (SD)
54 : 36h
1.059V
D/A 3 (T1)
192 : C0h
A/D 4 (ISENS)
177 : B1h
2.314V
D/A 4 (T2)
198 : C6h
A/D 5 (TEMPS)
186 : BAh 30.353'C
D/A 5 (T3)
204 : CCh 4.000V
A/D 6 (LVIN)
108 : 6Ch
2.118V
D/A 6 (T4/PWR)
114 : 72h
RX:174.00000MHz
TX:174.00000MHz
PWR : High
Base Freq : 174.00000MHz
Memory CH :
1
Power(Lo) : 72
Power(Hi)
: 142
MOD
: 80
BPF 1
:
2
BPF 2
: 54
BPF 3
: 92
BPF 4
:
4
[F9] at BPF : Sweep T1 ~ T4
[TAB] : Display Parameters
[F8] at BPF : Sweep
[Enter] at TXF : REF Set Mode
/
: Cursor Up/Down
/
: +/– ESC : Quit
FIELD PROGRAMMING SOFTWARE
5 - 1
GRADE AND RANGE
: 300–3000 Hz
: 1–500 mV
: 40 or 50 dB
: 10 W or more
: 120–500 MHz
: 0.1 µV–32 mV
(–127 to –17 dBm)
: 50 kΩ/V DC or better
: DC–20 MHz
: 0.01–20 V
: 10 mV–10 V
FIELD PROGRAMMING SOFTWARE
Boot up DOS, and
change the directory.
Start up command.
2.353V
2.569V
3.765V
Program starts up,
3.882V
2.235V
then the adjustment
screen appears after
reading set data from
the transceiver.
(Rev. 3.0 or later) from an

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IC-F3 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Ic-f3sIc-f4Ic-f4sIc-f3

Table of Contents