Application of Disassembly
Type B
S09
1. Remove the spring
2. Remove the needle bar supporter assy 2 from the shaft bushing 3 of the
base holder assy.
3. Remove the screw 1, and then remove the plate 1 from the needle bar
supporter assy 2.
4. Remove the screw 2, and then pull out the shaft 4 to remove the needle
bar supporter shaft 5 from the needle bar supporter assy 2.
2-14 Removal of Presser foot lifter
1. Remove the retaining ring E4 1, and then remove the presser foot lifter 2
from the shaft of base holder assy.
Upper shaft, Needle bar and Presser foot unit
from the plate 1 and the base holder assy.
<In case of Type A, refer to previous page.>