Degraded Raid Array; Missing Hard Drive Member; Failed Hard Drive Member - MSI MS-96E0 User Manual

(v1.x) server board
Table of Contents

Advertisement

d
raid a
eGraded
A RAID 1, RAID 5 or RAID 10 volume s reported as degraded when one of ts hard
drve members fals or s temporarly dsconnected, and data mrrorng s lost. As a
result, the system can only utlze the remanng functonal hard drve member. To re-
establsh data mrrorng and restore data redundancy, refer to the procedure below
that corresponds to the current stuaton.

Missing Hard Drive Member

1.
Make sure the system s powered off.
2.
Reconnect the hard drve.
3.
Reboot the system to Wndows; the rebuld wll occur automatcally.

Failed Hard Drive Member

1.
Make sure the system s powered off.
2.
Replace the faled hard drve wth a new one that s of equal or greater capacty.
3.
Reboot the system to Intel RAID Opton ROM by press <Ctrl> and <I> keys s-
multaneously durng the Power-On Self Test (POST).
4.
Select the port of the destnaton dsk for rebuldng, and then press ENTER.