Fujitsu D2799 Technical Manual

Fujitsu D2799 Technical Manual

For primergy tx200 s6

Advertisement

Technical Manual - English
System Board D2799
for PRIMERGY TX200 S6
Technical Manual
Edition July 2010

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu D2799

  • Page 1 Technical Manual - English System Board D2799 for PRIMERGY TX200 S6 Technical Manual Edition July 2010...
  • Page 2 – The contents of this manual may be revised without prior notice. – Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. – No part of this manual may be reproduced in any form without the prior written permission of Fujitsu.
  • Page 3 It has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk to life or body if such safety cannot be ensured. Technical Manual D2799 (TX200 S6)
  • Page 4 (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use.
  • Page 5 Only for the Japanese market: Although described in this manual, some sections do not apply to the Japanese market. These options and routines include: – USB Flash Module (UFM) – CSS (Customer Self Service) – Replacing the lithium battery Technical Manual D2799 (TX200 S6)
  • Page 6 Technical Manual D2799 (TX200 S6)
  • Page 7: Table Of Contents

    Switches ......35 Replacing the lithium battery ....37 Technical Manual D2799 (TX200 S6)
  • Page 8 Contents Technical Manual D2799 (TX200 S6)
  • Page 9: Introduction

    DVDs (see Installation DVD of ServerView Suite - ServerView Software Products). You will find further information about the BIOS setup in the "D2799 BIOS Setup Utility for TX200 S6" manual. PRIMERGY manuals are available in PDF format on the ServerView Suite DVD 2.
  • Page 10 Notational conventions Technical Manual D2799 (TX200 S6)
  • Page 11: Important Information

    Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. Technical Manual D2799 (TX200 S6)
  • Page 12 (this information doesn’t apply to the Japanese market). It is essential to observe the instructions in the chapter "Replacing the lithium battery". Technical Manual D2799 (TX200 S6)
  • Page 13 Do not touch any connectors or conduction paths on an ESD. Place all the components on a pad which is free of electrostatic charge. For a detailed description of how to handle ESD components, see the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20). Technical Manual D2799 (TX200 S6)
  • Page 14: Ce Certificate Of Conformity

    The board complies with the requirements of the EC directives 2004/108/EC regarding “Electromagnetic Compatibility” and 2006/95/EC “Low Voltage Directive”. This is indicated by the CE marking (CE = Communauté Européenne). Compliance was tested in a typical PRIMERGY configuration. Technical Manual D2799 (TX200 S6)
  • Page 15: Environmental Protection

    Environmental protection Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account.
  • Page 16 Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D-33106 Paderborn Tel.
  • Page 17: Features

    – up to 2 UDIMM memory rows per channel – ECC multiple-bit error detection and single-bit error correction – memory scrubbing functionality – Single Device Data Correction (SDDC) function (Chipkill™), only with RDIMMs – memory mirroring function – memory sparing function Technical Manual D2799 (TX200 S6)
  • Page 18 – 1x ATX power connector 24 pin (12V, -12V, 5V, 3.3V and 5V auxiliary) – 1x ATX power connector 8 pin (2x 12V) – 1x ATX power connector 10 pin (1x 12V) – 1x PC98 connector – 1x front panel connector Technical Manual D2799 (TX200 S6)
  • Page 19 – HD LED support (SAS, SATA) – Inventory Identification Control – pre-failure warranty for memory – CSS functionality – power consumption control – text console redirection – Advanced Video Redirection - AVR – remote storage Technical Manual D2799 (TX200 S6)
  • Page 20 – boot possible from: – hard disk (SATA, SAS, SCSI, USB) – USB stick – CD/DVD (IDE, SATA, SAS) – LAN – console redirection support – OEM logo – CPU, memory disable – Mirroring and Spare memory support Technical Manual D2799 (TX200 S6)
  • Page 21 USB stick connector. Internal USB stick (option) The system board can be equipped with an internal USB stick by the manufacturer. The internal USB stick can not be used together with an installed UFM. Technical Manual D2799 (TX200 S6)
  • Page 22 TPM or the system board is faulty you will not be able to access your data. – If a failure occurs, please inform your service about the TPM activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content. Technical Manual D2799 (TX200 S6)
  • Page 23: Main Memory

    DIMM1F DIMM2F DIMM1E DIMM2E DIMM1D CPU 1 DIMM2D CPU 2 DIMM2A DIMM1A DIMM2B DIMM1B DIMM2C DIMM1C Figure 2: Slots of the main memory – Minimum main memory configuration is 1 DIMM with Independent Channel Mode. Technical Manual D2799 (TX200 S6)
  • Page 24: Modes Of Operation

    Independent Channel Mode – Allows population of all channels in any order. Related to the channels (A-F) DIMM1 must be populated first. – Works with DIMMs of different clock rates and applies the lowest clock rate. Technical Manual D2799 (TX200 S6)
  • Page 25: Lv-Dimm Support

    800 MHz; operating voltage is set to 1.35 V "Performance" speed is set to 1333 MHz; operating voltage is set to 1.5 V The speed and operating voltage settings apply to all six sockets of one CPU in common. Technical Manual D2799 (TX200 S6)
  • Page 26: Pcie Slots

    32-bit / 33 MHz PCI slot PCIe x8 PCIe x8 slot; slot is open on the right side to plug in a x16 graphics card PCIe x8 PCIe x8 slot PCIe x4 PCIe x4 slot mechanical x8 connector Technical Manual D2799 (TX200 S6)
  • Page 27: Screen Resolution

    The following functions are supported: Temperature monitoring Measurement of the processor (each CPU has its own temperature sensor) and the system internal temperature by an onboard temperature sensor, measurement of the ambient temperature by a I C temperature sensor. Technical Manual D2799 (TX200 S6)
  • Page 28 BIOS Setup, iRMC S2’s Web interface or via the ServerView Operations Manager. PRIMERGY Local Diagnostic LEDs Optical signaling through the LEDs on the system board identifies defective modules and components (CSS functionality) as well as gaining information on the PDA (Prefailure Detection and Analysis). Technical Manual D2799 (TX200 S6)
  • Page 29: Connectors And Indicators

    Slot 4 PCI 32 Bit / 33 MHz Slot 3 iRMC Indicate PCIe x4 Slot 2 PCIe x4 Serial 2 SATA 6 SATA 5 Slot 1 stick Figure 5: Internal connectors of the system board D2799 Technical Manual D2799 (TX200 S6)
  • Page 30 USB Stick USB stick connector SATA MLC1 SATA MLC1 connector (4 port) uSSD Connector for USB Flash Module (UFM) SATA5 SATA5 connector SATA6 SATA6 connector Connector for TPM Serial 2 Connector for second serial connector Technical Manual D2799 (TX200 S6)
  • Page 31 LEDs are only visible, if the cover of the server has been opened. If the server has been powered off (power-plugs must be disconnected) it is possible to indicate the faulty component by pressing the CSS indicate button. Technical Manual D2799 (TX200 S6)
  • Page 32 E1 - overall All memory modules running memory Orange on At least one memory module defective E2 - memory Memory module running Orange on Memory module failure F - system Fan running fans Orange on Fan failure Technical Manual D2799 (TX200 S6)
  • Page 33: Connector Panel

    The serial connector COM1 can be used as default interface or to communicate with the iRMC S2. LAN connectors ® The system board is equipped with an Intel Gigabit Ethernet controller (Intel 82574L). The LAN controller supports transmission rates of 10 Mbit/s, 100 Mbit/s and 1 Gbit/s. Technical Manual D2799 (TX200 S6)
  • Page 34 Steady yellow signal in the event of a LAN transfer (shared LAN) rate of 1 Gbit/s Steady green signal in the event of a LAN transfer rate of 100 Mbit/s. Remains dark in the event of a LAN transfer rate of 10 Mbit/s. Technical Manual D2799 (TX200 S6)
  • Page 35: Settings

    Switch 1 enables recovery of the old system BIOS after an attempt to update has failed. To restore the old system BIOS you need a Flash BIOS medium (see the BIOS manual or please call our customer service centre). Technical Manual D2799 (TX200 S6)
  • Page 36 Settings Technical Manual D2799 (TX200 S6)
  • Page 37: Replacing The Lithium Battery

    Ê Press the locking spring into direction of the arrow (1), so that the lithium battery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). Technical Manual D2799 (TX200 S6)
  • Page 38 Replacing the lithium battery Technical Manual D2799 (TX200 S6)

Table of Contents