  • Page 1 System Board D2785 for TX120 S2 Technical Manual Edition April 2009...
  • Page 2 Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by e-mail to manuals@ts.fujitsu.com. Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and...
  • Page 3: Table Of Contents

    Replacing the lithium battery ....27 Abbreviations ....... 29 Technical Manual D2785 (TX120 S2)
  • Page 5: Introduction

    Introduction This technical manual describes the system board D2785, which is equipped ® with one Intel processor. You will find further information in the manual “BIOS Setup”. Further information about drivers is provided in the readme files on the hard disk, or on the supplied CDs/DVDs.
  • Page 7: Important Notes

    Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. Technical Manual D2785 (TX120 S2)
  • Page 8 It is essential to observe the instructions in chapter “Replacing the lithium battery”. Modules with electrostatic-sensitive components Boards with electrostatic sensitive devices (ESD) are marked with the following label: Figure 1: ESD label Technical Manual D2785 (TX120 S2)
  • Page 9 EMI spring contacts Be careful with the locking mechanisms (catches, centring pins etc.) when you replace the system board or components on it, for example memory modules or processors. Never use sharp objects (screw drivers) for leverage. Technical Manual D2785 (TX120 S2)
  • Page 10: Ce Certificate Of Conformity

    ENERGY STAR guidelines for energy efficiency. These servers are always delivered with a particular setting in the BIOS setup. For details please see the manual “D2785 BIOS Setup Utility for PRIMERGY TX120 S2” on the PRIMERGY ServerView Suite DVD 2. Technical Manual...
  • Page 11: Environmental Protection

    Cd Cadmium Hg Mercury Pb Lead Labels on plastic casing parts Please avoid sticking your own labels on plastic parts wherever possible, since this makes it difficult to recycle them. Technical Manual D2785 (TX120 S2)
  • Page 12 Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu Technology Solutions branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D-33106 Paderborn Tel.
  • Page 13: Features

    – local BIOS update via bootable USB device – remote BIOS update via LAN – Onboard iRMC S2 Server Management controller with integrated graphic controller and associated service LAN connector – ADT7462 temperature and system monitoring controller Technical Manual D2785 (TX120 S2)
  • Page 14 – 1 x PCI (32 Bit / 33 MHz) expansion slot – 3 x PCI Express x8 expansion slots BIOS Phoenix System BIOS V 4.06 (Trusted Core) Environmental protection Battery in holder Form factor, slot compatibility list 260 mm x 305 mm Technical Manual D2785 (TX120 S2)
  • Page 15 TPM or the system board is faulty you will not be able to access your data. – If a failure occurs, please inform your service about the TPM activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content. Technical Manual D2785 (TX120 S2)
  • Page 16: Main Memory

    The dual channel mode is only activated, if the memory size installed in the DIMM-2A slot is equal to the sum of the memory modules installed in the DIMM-1A and DIMM-1B slots. (e. g.: DIMM-1A=1GB, DIMM-1B=1GB, DIMM-2A=2GB) Technical Manual D2785 (TX120 S2)
  • Page 17: Pci Bus

    An interrupt signal may thereby be used simultaneously by multiple devices (interrupt sharing). PCI Express devices send their interrupts through messages. This avoids restrictions in wiring. Technical Manual D2785 (TX120 S2)
  • Page 18: Screen Resolution

    32 Bit 1024x768 32 Bit 1152x864 24 Bit 1280x1024 24 Bit If you are using a different graphic controller, you will find details of supported screen resolutions in the documentation supplied with the graphic controller. Technical Manual D2785 (TX120 S2)
  • Page 19: Temperature / System Monitoring

    When voltage exceeds warning level high or falls below warning level low an alert will be generated. System Event Log (SEL) All monitored events of the system board are recorded in the System Event Log. They could be retrieved after a reboot via ServerView. Technical Manual D2785 (TX120 S2)
  • Page 20: Connectors And Indicators

    Upper BPL I2C CONN Intel FRONT LAN FAN1 ATX PWR1 DRIVE Intel ICH9-R Battery SATA SATA MLC1 iRMC S2 Intel 82567 USB 7/8 Service COM1 3/4/6 Figure 4: Internal connectors of the system board D2785 Technical Manual D2785 (TX120 S2)
  • Page 21 USB connector for optional backup drive SATA connector SATA MLC1 connector Connector for TPM Onboard diagnostic LED iRMC S2 Figure 5: Detail - Diagnostic LED The LED has the following meaning: Indicator Meaning green flashing iRMC S2 is healthy Technical Manual D2785 (TX120 S2)
  • Page 22: Connector Panel

    Connectors and indicators Features 3.6.2 Connector panel Figure 6: Connector panel of the system board D2785 No. Description Serial interfaceCOM1 (turquoise) Monitor connector VGA (blue) Service LAN connector LAN connector 5x USB connectors (black) LAN connectors On this system board you will find a Gigabit Ethernet controller with Intel 82567 LM integrated in the Intel ICH9-R chipset.
  • Page 23 Flashes yellow in the event of a LAN transfer rate of (standard LAN) 1 Gbps Steady green signal in the event of a LAN transfer rate of 100 Mbps. Remains dark in the event of a LAN transfer rate of 10 Mbps. Technical Manual D2785 (TX120 S2)
  • Page 24: Jumpers

    Connectors and indicators Features 3.6.3 Jumpers Intel Intel ICH9-R Battery iRMC S2 Intel 82567 USB 7/8 Service COM1 3/4/6 Figure 8: Jumpers of the system board D2785 Technical Manual D2785 (TX120 S2)
  • Page 25 BIOS floppy disk“ (via an external USB floppy disk drive) and repro- grams the system BIOS on the system board. BIOS 1-2 (standard) The password query is skipped. password Passwords are deleted. recovery The password query is effective. Technical Manual D2785 (TX120 S2)
  • Page 27: Replacing The Lithium Battery

    Ê Press the locking spring into direction of the arrow (1), so that the lithium- battery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). Technical Manual D2785 (TX120 S2)
  • Page 29: Abbreviations

    Automatic Server Recovery and Restart Advanced Technology Attachment Battery Backup Unit BIOS Basic Input Output System Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COMmunication port Customer Replaceable Unit Customer Self Service Central Processing Unit Technical Manual D2785 (TX120 S2)
  • Page 30 Dynamic Random Access Memory Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic Electrostatic Discharge EVRD Enterprise Voltage Regulator Down Fully Buffered DIMM Hard Disk Drive Technical Manual D2785 (TX120 S2)
  • Page 31 Intelligent Organization Of PCI IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface iRMC integrated Remote Management Controller Local Area Network Light Emitting Diode Memory Controller Hub Multi Processor Specification Non Maskable Interrupt Network Operating System Technical Manual D2785 (TX120 S2)
  • Page 32 Operating System Peripheral Components Interconnect Prefailure Detection and Analyzing Programmed Input Output Programmable Logic Device POST Power-On Self Test PS(U) Power Supply (Unit) Puls Wide Modulation Preboot eXecution Environment RAID Redundant Array of Inexpensive Disks Technical Manual D2785 (TX120 S2)
  • Page 33 SCSI Small Computer Systems Interface SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server Hardware Design Guide SHPC Standard Hot Plug Controller System Management Bus Server Management Mode Symmetrically Multi Processing Technical Manual D2785 (TX120 S2)
  • Page 34 Abbreviations Solid-State Drive Trusted Platform Module UHCI Unified Host Controller Interface Universal Serial Bus Video Graphics Adapter Voltage Regulator Down Voltage Regulator Module Wired for Management Wake up On LAN Technical Manual D2785 (TX120 S2)

Table of Contents