Daikin Quaternity FTXG09HVJU Engineering Data page 13

H series split-system room air conditioners
Hide thumbs Also See for Quaternity FTXG09HVJU:
Table of Contents

Advertisement

Capacity Tables
Symbols
AFR
: Airflow rate
BF
: Bypass factor
EWB
: Entering wet bulb temp.
EDB
: Entering dry bulb temp.
TC
: Total capacity
SHC
: Sensible heating capacity (kW) / (kBtu/h)
PI
: Power input
12
Note:
(m
/min.)
1. Ratings shown are net capacities which include a deduction for indoor fan
3
motor heat.
2.
3. TC, PI and SHC must be calculated by interpolation using the figures in
(°C) / (°F)
the above tables. (Figures out of the tables should not be used for
(°C) / (°F)
calculation.)
4. About SHC which are not mentioned on the table, please calculate them
(kW) / (kBtu/h)
with around values in direct proportion.
5. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25ft (7.5 m)
(kW)
Level difference : 0ft
6. Airflow rate (AFR) and Bypass factor (BF) are tabulated above table.
7. Cooling capacity at -10 degrees Celsius / 14 degrees Fahrenheit.
shows nominal (rated) capacities and power input.
Temp: Celsius / TC, SHC, PI: kW
INDOOR
OUTDOOR
EWB
EDB
-10 (°CDB)
°C
°C
TC
SHC
PI
14.0
20
3.65
2.66
0.47
Temp: Fahrenheit / TC, SHC: kBtu / PI: kW
INDOOR
OUTDOOR
EWB
EDB
14 (°FDB)
°F
°F
TC
SHC
PI
57.2
68.0
12.45
9.08
0.47
EDUS04-906
3D063099A
Room Air Conditioners H-Series