PRE-INSTALLATION
3.7

FLUE OPTIONS

The Greenstar CDi has the option of three horizontal RSF (60/100
telescopic, 60/100 longer telescopic and 80/125 telescopic) flue
systems and two vertical RSF (60/100 or 80/125) regular flue systems:
The systems have different maximum flue lengths for different boiler
outputs and different plume management lengths.
For every extra 1000mm of plume management after the first 500mm,
the internal 60/100 flue length must be reduced by 700mm, up to a
maximum of 4500mm of plume management.
For example on a 30CDi if the plume management effective length was
1500mm, the internal flue would be reduced to 5200mm.
Maximum horizontal flue lengths (L)
Boiler model
100mmØ
No Plume
+ 500mm
management
of plume
management
30CDi
7,900mm
5,900mm
40CDi
6,000mm
4,000mm
Table 6 Maximum horizontal flue lengths
Maximum vertical flue lengths
Boiler model
100mmØ
30CDi
9,400mm
40CDi
7,500mm
Table 7 Maximum vertical flue lengths
This page and the page opposite shows various flue options with the
straight flue lengths required to achieve the maximum flue length.
NOTICE: 60/100 Flue systems:
▶ Each 90° bend used is equivalent to 1.5 metres of
straight flue.
▶ Each 45° bend used is equivalent to 0.75 metres of
straight flue.
NOTICE: 80/125 flue systems:
▶ Each 90° bend used is equivalent to 2 metres of
straight flue.
▶ Each 45° bend used is equivalent to 1 metre of
straight flue.
Telescopic horizontal flue
Flue option 1
100mmØ
30CDi
570mm
40CDi
570mm
Table 8 Flue option 1
Horizontal extended flue
Flue option 2
100mmØ
30CDi
7,900mm
40CDi
6,000mm
Table 9 Flue option 2
Horizontal extended flue with 1x90° bends
Flue option 3
100mmØ
30CDi
6,400mm
40CDi
4,500mm
Table 10 Flue option 3
14
125mmØ
+4500mm
No plume
of plume
management
management
available
3,100mm
18,500mm
1,200mm
12,500mm
125mmØ
18,500mm
16,000mm
125mmØ
600mm
600mm
125mmØ
18,500mm
12,500mm
125mmØ
16,500mm
10,500mm
Horizontal extended flue with 2x90° bends
Flue option 4
100mmØ
30CDi
4,900mm
40CDi
3,000mm
Table 11 Flue option 4
High level horizontal extended flue
Flue option 5
100mmØ
30CDi
7,900mm
40CDi
6,000mm
Table 12 Flue option 5
High level horiz. extended flue with 2x90° bends
Flue option 6
100mmØ
30CDi
6,400mm
40CDi
4,500mm
Table 13 Flue option 6
High level horiz. extended flue with 3x90° bends
Flue option 7
100mmØ
30CDi
4,900mm
40CDi
3,000mm
Table 14 Flue option 7
Vertical balanced extended flue
Flue option 8
100mmØ
30CDi
9,400mm
40CDi
7,500mm
Table 15 Flue option 8
Vertical balanced extended flue with 2x90° bends
Flue option 9
100mmØ
30CDi
6,400mm
40CDi
4,500mm
Table 16 Flue option 9
Vertical balanced extended flue with 2x45° bends
Flue option 10
100mmØ
30CDi
7,900mm
40CDi
6,000mm
Table 17 Flue option 10
125mmØ
14,500mm
8,500mm
125mmØ
18,500mm
12,500mm
125mmØ
16,500mm
10,500mm
125mmØ
14,500mm
8,500mm
125mmØ
18,500mm
16,000mm
125mmØ
14,500mm
12,000mm
125mmØ
16,500mm
14,000mm
6 720 806 548 (2013/02)